The screen shows a filter period, in % of the total pumping
phase, in which a possible opening of the over-pressure
relieve valve will be ignored by the program. The maximum
setting is 50% calculated from the end of the pumping
phase, which means that during the second half of the
pumping phase valve openings will be ignored.
The standard setting is 25%, ignoring possible valve
openings during the last 1/4 of the pumping phase.
Openings during the first 3/4 will cause a “release during
grease” (rdg) error and trigger the lamp for the rest of the
pumping phase.
If necessary, change this setting and confirm with <ENTER>.
Press <F2> (
poct
).
The screen shows the amount of time (in milliseconds) the
control unit tolerates an overcurrent or short-circuit in the
electric motor of the pump, before it disconnect the electric
motor.
The default is 50 ms and value should not be changed.
Press <F3> (
loct
).
The screen shows the amount of time (in milliseconds) the
control unit tolerates an overcurrent or short-circuit in the
signal light circuit, before it disconnect the signal light.
The default is 10 ms and value should not be changed.
Press <F4> (
end1
).
The screen shows the number of grease cycles within at least
1 pulse of the end- (block) switch (optional) must been
received, to prevent an error. The setting should be 0 when
no end-switch is installed.
If necessary, change this setting and confirm with <ENTER>.
PARAMETERS TIMER
Max release errors
xxx [%]
mre poct loct end1
PARAMETERS TIMER
Pump oc time
xxx [msec]
mre poct loct end1
PARAMETERS TIMER
Lamp oc time
xxx [msec]
mre poct loct end1
PARAMETERS TIMER
End line switch
xxx [cycles]
mre poct loct end1