Automatic Greasing System
TriPlus Trailer
The GINA
19
Date of
is
sue :
Sept
e
m
ber
2
012
F212157R02
3.2
Connecting the GINA
The supply voltage of the control unit to be read or programmed must be available (from the
vehicle or an external power supply, if need be).
Connect the GINA with the control unit, using the supplied interconnection cable.
3.3
Control pad
3.4
Switching on the GINA
The GINA can be switched-on after:
•
the GINA has been connected with the control unit, and
•
the power supply has been available to the control unit for at least 8 seconds.
Press <POWER ON/OFF>.
You can access the main menu, parameters timer and diagnosis menu by pressing, respectively
<MAIN>, <PARAMETERS> or <DIAGNOSIS>.
This message appears when the GINA is unable to communicate with the control unit:
This can be cause by:
•
bad connection (wire in cable broken or bad connector).
•
GINA switched-on too quickly.
Always try to alleviate the problem first by turning the GINA off and then on again, or by pressing
one of the softkeys (<F1>, <F2>, <F3> or <F4>).
Key
Function
<POWER ON/OFF>
to turn the GINA on or off (toggle)
<F1> .. <F4>
('soft keys') to make a particular choice in a menu
<0> .. <9>
to enter numerical data
<MAIN>
to call the main menu to view miscellaneous information
<PARAMETERS>
to call the parameter menu to view and enter parameter data
<DIAGNOSIS>
to call the diagnosis menu to view various system data
<NEXT>
to go to the next screen in the menu system
<ENTER>
to confirm a setting you have changed or entered
Communication error