-18-
Model g0661/g0713 (Mfg. since 1/10)
Voltage Conversion
this section shows how to convert the Model
g0661 from 220V to 110V and the Model g0713
from 110V to 220V.
Items Needed
Qty
•
phillips head screwdriver #2 ..................... 1
•
Electrical tape ............................ as needed
•
Wire nut (14 aWg x 3) .............................. 1
•
5-20 plug (g0661) or 6-15 plug (g0713) .. 1
Figure 6. Model g0661 rewired to 110V.
HiVgi
8VeVX^idg
'%%B;9
'*%K68
Gjc
8VeVX^idg
(%B;9
(*%K68
<gdjcY
'
)
&
(
Connect
Wires with
nuts here
4. Close and secure the motor junction box.
5. remove the 5-15 plug from the power cord
and install a 6-15 plug (refer to wiring dia-
gram on
page 79).
3. use wire nuts to conect the wires as indicated
in
Figure 8. twist both wire nuts onto their
respective wires and wrap them with electri-
cal tape so they will not come loose. retain
the wire nut on the brown wire.
HiVgi
8VeVX^idg
'%%B;9
'*%K68
Gjc
8VeVX^idg
(%B;9
(*%K68
<gdjcY
'
)
&
(
Figure 8. Model g0713 rewired to 220V.
Connect
Wires with
nuts here
Converting Model G0713 to 220V
1. disConnECt saW FroM poWEr!
2. open the motor junction box, then loosen the
wires indicated in
Figure 7.
<gdjcY
HiVgi
8VeVX^idg
'%%B;9
'*%K68
Gjc
8VeVX^idg
(%B;9
(*%K68
'
)
&
(
Figure 7. location of wire nuts to be loosened
on Model g0713.
loosen
these
Wire nuts
Figure 5. location of wire nuts to be loosened
on Model g0661.
HiVgi
8VeVX^idg
'%%B;9
'*%K68
Gjc
8VeVX^idg
(%B;9
(*%K68
<gdjcY
&
(
'
)
loosen
these
Wire nuts
3. use wire nuts to connect the wires as indi-
cated in
Figure 6. twist both wire nuts onto
their respective wires and wrap them with
electrical tape so they will not come loose.
4. Close and secure the motor junction box.
5. remove the pre-installed 6-15 plug from the
power cord and install a 5-20 plug on the end
of the cord, as illustrated in the wiring dia-
gram on
page 78.
NOTICE
Refer to the motor junction box cover dia-
gram for connection locations and voltage
conversion. If a diagram is not present,
use the instructions below, or call our Tech
Support Department at (570) 546-9663.
Converting G0661 to 110V
1. disConnECt saW FroM poWEr!
2. open the motor junction box, then loosen the
wire nuts indicated in
Figure 5.