MicroGuard 510 Upgrade
10
Each button acts as a toggle switch turning the alarm on or off if the alarm is off, press the
appropriate push button to turn the alarm on. If the alarm is on, press the appropriate push button to
turn the alarm off.
Setting minimum Boom Angle Alarm
Move the boom to the desired minimum angle. Press
the
operaTor alarm
key to access the operator
alarm screen. Press the key adjacent to “Min Angle”
to set to the current position.
If the angle of the boom falls below the minimum
angle set, the red warning light will flash and the
audible alarm will sound.
Press the key adjacent to “Min Angle” again to turn of
the minimum boom angle alarm.
Setting maximum Boom Angle Alarm
Move the boom to the desired maximum angle. Press the
operaTor alarm
key to access the
operator alarm screen. Press the key adjacent to “Max Angle” to set the current position.
If the angle of the boom rises above the maximum angle set, the red warning light will flash and the
audible alarm will sound.
Press the key adjacent to “Max Angle” to turn off the maximum boom angle alarm.
Setting maximum Boom length Alarm
Move the boom to the desired maximum
length
, in
this example 78 ft. Press the Operator Alarm Button
to access the Operator Alarm Screen. Press the Max
Height Button. The display will read Max Height 78 ft.
The red warning light will flash and the audible alarm
will sound whenever the Boom Tip Height exceeds 78
ft. Pressing the Max Height button again will cancel
the alarm and the display will read Max Height Off.
Setting maximum Tip height Alarm
Move the boom to the desired maximum height, in this example 78 ft. Press the Operator Alarm
Button to access the Operator Alarm Screen. Press the Max Height Button. The display will read Max
Height 78 ft. The red warning light will flash and the audible alarm will sound whenever the Boom Tip
Height exceeds 78 ft. Pressing the Max Height button again will cancel the alarm and the display will
read Max Height Off.
Accessing Swing and Work Area Alarms
To access the swing and work area alarms from the
main working screen, press the
operaTor alarm
key twice. The information window will show the
current status of the swing and work area alarms.
Each of the four operator alarms are controlled by
keys adjacent to the text in the information window.
Each push button operates as a toggle switch. If
the alarm to be set is off, pressing the push button
TEST
SET
MAX
TEST
SET
MAX
TEST
SET
MAX
W450520 0