MicroGuard 510 Upgrade 

Counterweight

On cranes that have counterweight options the 
operator must tell the system which counterweight 
is currently fitted. If the counterweight push button is 
pressed on a crane that does not have counterweight 
options, the message “No Other Counterweight 
Options” will appear in the information window.

Outriggers

The operator must tell the system which outrigger 
position is in use. These positions range from fully 
extended to half extended, or from half-extended to 
fully retracted and then back to fully extended. If no 
other selections are available, the message, “No Other 
Chassis Options” will appear in the information window.

Tires and rigging/Travel

On cranes that have more than one tire option, e.g. 
static, creep etc., the operator must select the tire 
configuration that corresponds to the tire chart to be 
used. If the tire push button is pressed on a crane that 
does not have tire options, the message “No Other Tire 
Options” will appear in the information display. Refer to 
your crane rating manual for details of the options on 
your crane.

m

WArnIng

DO nOT PErFOrm CrAnE lIFTIng OPErATIOnS WhIlE ThE rIggIng/TrAVEl mODE IS 

SElECTED. All CrAnE COnTrOlS rEmAIn ACTIVE WhIlE ThE rIggIng/TrAVEl mODE IS 

SElECTED.

Stowing the Jib

The stowed jib button will select between stowed jib 
or no stowed jib. The stowed jib button is also used to 
stow the erected jib. For cranes that do not have jib 
options, the message “No Other Stowed Jib Options” 
will appear in the information window.

TEST

SET

MAX

COUNTERWEIGHT

TEST

SET

MAX

OUTRIGGERS

TEST

SET

MAX

TIRES

TEST

SET

MAX

STOWED JIB

W450520 0

7 2020

Summary of Contents for MicroGuard RCI 510

Page 1: ...MicroGuard RCI 510 Upgrade Rated Capacity Indicator System For Telescopic Boom Cranes Operation...

Page 2: ......

Page 3: ...rast 6 Counterweight 7 Outriggers 7 Tires and Rigging Travel 7 Stowing the Jib 7 Erecting the Jib 8 Auxiliary Head 8 Selecting the Winch 8 Setting the Parts of Line 9 Cancel Alarm Button 9 Reset Funct...

Page 4: ...MicroGuard 510 Upgrade ii W450520 07 2020...

Page 5: ...the extension of the boom A cable attached to the boom head provides a low current electrical path for the ATB signal Pressure Transducers Two pressure transducers measure the pressure in the boom ho...

Page 6: ...These alarms can be programmed for each job site and allow the operator to work in a defined area Boom Angle Sensor Boom angle is measured by means of a high accuracy potentiometer pendulum assembly...

Page 7: ...are defined below 2 1 3 4 5 6 8 7 9 1 Jibs Indicates the configuration of an erected jib 2 Aux Head Illuminates when the auxiliary head is fitted 3 Point Of Lift Switches between boom auxiliary head a...

Page 8: ...r Shows the load as a percentage of rated capacity As the load increases the meter level increases to represent the percentage of the rated capacity of the crane 6 Rated Capacity Displays the rated ca...

Page 9: ...gnostics 15 Input Select Select and enter calibration information 16 Operator Alarm Set Enables operator alarms When an alarm has been set the LED above this button will illuminate yellow mWarning You...

Page 10: ...r The screen is a reminder to read important documentation before proceeding with operation of the system Adjusting Brightness Contrast Immediately following self test and the start up screen the info...

Page 11: ...re than one tire option e g static creep etc the operator must select the tire configuration that corresponds to the tire chart to be used If the tire push button is pressed on a crane that does not h...

Page 12: ...ave an auxiliary head the message No Other Auxiliary Head Options will appear in the information screen Selecting the Winch For cranes with two winches always select the winch to be used for the lift...

Page 13: ...proximately five seconds to reset the relay and another beep will be heard confirming the override The override condition will remain in effect only as long as the cancel key is held When the cancel k...

Page 14: ...desired maximum length in this example 78 ft Press the Operator Alarm Button to access the Operator Alarm Screen Press the Max Height Button The display will read Max Height 78 ft The red warning ligh...

Page 15: ...m is activated when swinging to the right In this example the working arc is the smaller piece of the pie A left swing alarm is activated when swinging to the left A right swing alarm is activated whe...

Page 16: ...Press the keys adjacent to Left Swing and Right Swing so they show off Rotate the boom to the left swing point and press the key adjacent to Left Swing then press the key adjacent to Next to proceed...

Page 17: ...ress the key adjacent to Next to proceed Rotate the boom to the right swing point and press the key adjacent to Off Press the key adjacent to Finish to complete the routine TEST SET MAX TEST SET MAX T...

Page 18: ...E mWarning The Operator Defined Work Area Alarm Is a Warning Device All Functions Remain Operational When Entering The Operator Defined Exclusion Zone Safe Working Distance is the time it would take t...

Page 19: ...reached this will avoid having to pass through the exclusion zone This is the point to the right facing the exclusion zone to be defined Press the key adjacent to Right Point To deactivate the swing a...

Page 20: ...lsa Winch Group www dovertwg com As a leader in product innovation Greer Company is committed to the ongoing improvement of its equipment We reserve the right to make changes to our products without n...

Reviews: