MicroGuard 510 Upgrade
9
Setting the Parts of line
Parts of line are set by pressing the up or down
arrow. The number of parts of line will appear in the
display next to the arrow. When an alternate winch is
selected, it is necessary to reset the parts of line for
the alternate winch.
Cancel Alarm Button
When an alarm condition occurs, the warning horn
can be silenced by pressing the
CanCel
key. The
system will reactivate the warning horn when another
alarm condition occurs.
reset Function Kick-Out
Reset function kick-out override is used to reposition the boom when the crane is being rigged. If the
boom is topped out, it is often necessary to put the boom in a position that could cause function kick-
out. Press and hold the
CanCel
key for approximately five seconds to reset the relay and another
beep will be heard confirming the override. The override condition will remain in effect only as long as
the
CanCel
key is held. When the
CanCel
key is released, the system will return to locked out mode
until the condition it is corrected. Should a different alarm condition occur while the relay is over-
ridden, the new alarm condition will cause the controls to disconnect again.
m
WArnIng
WhEn ThE rESET FunCTIOn KICK-OuT OVErrIDE FunCTIOn IS uSED, ThErE IS nO
PrOTECTIOn FrOm OVErlOAD Or TWO-BlOCK COnDITIOn.
Operator Settable Alarms
Accessing the Operator Alarms
Press the operator alarms button to access the
operator alarms. The information window will show
the current status of the alarms. The following
operator alarms are available:
•
Minimum Boom Angle
•
Maximum Boom Angle
•
Maximum Boom Length
•
Maximum Tip Height
TEST
SET
MAX
PARTS OF LINE
TEST
SET
MAX
CANCEL
TEST
SET
MAX
W450520 0
7 2020