t
op
v
ent
a
Daptor
k
It
& 3” (76
mm
)
to
6” (152
mm
) f
lue
a
Daptor
(
approveD
for
vertIcal
InStallatIonS
only
)
*In order to achieve the maximum
rated efficiency of 80.2% HHV
purchase of a top vent adaptor kit
(GF40-920) is required.
Use the sheet metal screws
provided to attach the kit to the
rear of the unit as shown. Please
see kit instruction manual for more
detailed installation instructions.
The stove must also be connected
to a 6” (152 mm) Class A flue
(where permitted) using the 3”
(76 mm) to 6” (152 mm) Flue
Adaptor (3PVP-X6).
See separate instruction manual
for complete details.
t
hermoStat
I
nStallatIon
:
1. Install the wall thermostat in a location that is not too close to the unit but will effectively heat the desired area.
2. Install a 12 or 24 Volt Thermostat using an 18 x 2 gauge wire from the unit to the thermostat.
If the unit has been placed in the HI / LOW mode, the unit will
be taken to a low or idle setting when the thermostat is not
calling for heat. When the thermostat calls for heat, the unit
will go to the setting that is displayed on the control board
Heat Indicator.
Connect Thermostat
wires here.
Thermostat Wire Placement
GF40-920
3PVP-X6
Note:
Part # 6DVL-ADT Simpson Duravent DVL adaptor would
also be required to connect the 3" (76 mm) - 6" (152 mm)
increaser to class A chimney when going through the wall
or ceiling when using Simpson Duravent Duraplus/Duratech
chimney systems. Not required with DuraTech Premium or
DuraTech Canada. DTC ceiling supports feature a built-in
flue extension which eliminates the need for this Simpson
Duravent DVL adaptor.
3" (76 mm) pipe
lengths to class A
chimney
GF40 Freestanding Pellet Stove |