c
learanceS
to
c
ombuStIbleS
These dimensions are minimum clearances but it is recommended that you ensure sufficient room for servicing, routine
cleaning and maintenance.
Note: This clearance is also required for air space between the appliance and wall/ceiling.
Clearances to combustibles are for the safety of the property. To avoid overheating and damaging the appliance these
clearances should be maintained for non-combustibles also.
A. Side wall to unit
8 inches (200 mm)
B. Back wall to unit 5-1/2 inches (140 mm)
C. Back wall to Chimney Connector 4 inches (100mm)
D. Corner to unit
3 inches (75 mm)
E. Glass to Hearth Pad
6 inches (150 mm)
F. Glass to Hearth Pad
7-3/8 inches (187 mm)
Figure 3: Minimum Install Clearances
E
B
A
D
C
F
12
| GF40 Freestanding Pellet Stove
|
12
installation