1. AUGER LIGHT:
This green light will flash in conjunction with the auger pulse.
2. MODE LIGHT:
Responsible for signaling the state of the control board. When the light is flashing
the stove is in an automatic start mode or the thermostat has control of the unit.
When the light is solid, the Heat Level Setting can be altered.
3. THERMOSTAT SWITCH:
Used to set the unit’s controls to one of three mode settings; Manual, High/Low, or
Auto/Off.
4. FEED RATE TRIM BUTTON:
Used to change the feed rate trims in ¼ second increments for all feed settings.
When this button is pressed, all the light will light up on the Heat Output Indicator
except for the one that shows the current setting; the default setting is the number 4
light. To adjust the setting hold the Feed Rate Trim button down and press the Heat
Level up or down buttons to adjust the setting.
5. COMBUSTION BLOWER TRIM BUTTON:
Used to change the Combustion Blower trims in 5 volt increments for all feed settings
until it reaches line voltage. When this button is pressed, all the light will light up
on the Heat Output Indicator except for the one that shows the current setting;
the default setting is the number 2 light. To adjust the setting hold the Combustion
Blower Trim button down and press the Heat Level up or down buttons to adjust
the setting.
6. ON/OFF BUTTON:
Used to turn the unit On and Off.
7. ROOM AIR FAN ON/OFF BUTTON:
Used to turn convection fan On or Off.
8. HEAT LEVEL ADJUSTMENT BUTTONS:
When pressed, will change the heat level setting of the unit up or down.
9. HEAT OUTPUT INDICATOR:
Shows the present heat output setting.
a
utomatIc
S
afety
f
eatureS
of
y
our
p
ellet
S
tove
A. The stove and insert have a low limit safety switch located on the housing of the exhaust blower. If the exhaust temperatures
drop below 120°F (49°C) the unit will shut down and will be required to go through a full start up procedure again. You
will see a flashing #3 Error code. The most common cause for this is an empty hopper. This switch should only be by-
passed for testing purposes by a technician.
B. The stove has a high limit safety switch located just below the hopper behind the external body panels. If the temperature
of this switch reaches 200°F (93°C) the auger will stop feeding fuel and the unit will shut down.There will be a flashing
#4 error code. The 200°F (93°C) switch is a manual reset and should only be reset by a service person who can first
diagnose the reason for failure. The two most likely causes are Convection Fan failure or High Limit Switch failure. Either
one needs to be properly diagnosed and rectified. Since this is a safety switch it should never be by-passed for any reason
other than the service technician to test the operation.
GF55-094
New
ROOM AIR
FAN ON/OFF
HEAT LEVEL
AUTO/OFF
HIGH/LOW
MANUAL
AUGER
MODE
ON/OFF
FEED
TRIM
COMBUSTION
AIR TRIM
GF55-094
Original
ROOM AIR
FAN ON/OFF
HEAT LEVEL
AUTO/OFF
HIGH/LOW
MANUAL
AUGER
MODE
ON/OFF
FEED
TRIM
COMBUSTION
AIR TRIM
1
6
5
4
3
2
9
8
7