ASHES:
Disposed ashes should be placed in a metal container with a tight fitting lid. The closed container of
ashes should be on a non-combustible floor on the ground, well away from all combustible materials pending final
disposal. If the ashes are disposed of by burial in soil or otherwise locally dispensed, they should be retained in the
closed container until all cinders have been thoroughly cooled.
ELECTRICAL: The use of a surge protected power bar is highly recommended.
The unit must be grounded.
The grounded electrical cord should be connected to a standard 110-120 volts, nominal average 2.0 Amps (4.1
Amps peak), and 60 hertz electrical outlet also must be accessible. Ensure the polarity to the outlet the unit will
be plugged into is correct as incorrect polarity can affect the unit’s operation. If this power cord should become
damaged, a replacement power cord must be purchased from the manufacturer or a qualified Regency dealer. Be
careful that the electrical cord is not trapped under the appliance and that it is clear of any hot surfaces or sharp
edges. This unit’s maximum power requirement is 184 watts (600 watts peak).
GLASS:
Do not abuse the glass by striking or slamming the door. Do not attempt to operate the stove with
broken glass. The stove uses ceramic glass. Replacement glass must be purchased from an Regency dealer. Do
not attempt to open the door and clean the glass while the unit is in operation or if glass is hot. To clean the glass,
use a soft cotton cloth and mild window cleaner, gas or wood stove glass cleaner, or take a damp paper towel and
dip into the fly ash. This is a very mild abrasive and will not damage the glass.
FLAMMABLE LIQUIDS:
Never use gasoline, gasoline-type lantern fuel, kerosene, charcoal lighter fluid, or similar
liquids to start or “freshen up” a fire in the heater. Keep all such liquids well away from the heater while it is in use.
SMOKE DETECTOR:
Smoke detectors should be installed and maintained in the structure when installing and
operating a pellet burning appliance.
OPERATION:
The ash pan and door must be closed securely for proper and safe operation of the pellet stove.
Also ensure all gaskets on the door are checked and replaced when necessary.
KEEP ASH PAN FREE OF RAW FUEL.
Do not lace unburned fuel or new fuel in ash pan. A fire in the ash pan may occur.
INSTALLATION:
Be sure to maintain the structural integrity of your home when passing a vent through walls,
ceilings, or roofs. It is recommended that the unit be secured into its position in order to avoid any displacement.
DO NOT INSTALL A FLUE DAMPER IN THE EXHAUST VENTING SYSTEM OF THIS UNIT.
DO NOT CONNECT THIS UNIT TO A CHIMNEY FLUE SERVING ANOTHER APPLIANCE.
FRESH AIR:
Outside Fresh Air connection is optional. Must be connected to all units installed in Mobile and “Air
Tight Homes” (R2000) or where required by local codes. Consider all large air moving devices when installing your
unit and provide fresh air accordingly. Limited air for combustion may result in poor performance, smoking and
other side effects of poor combustion.
If you have any questions with regards to your stove or the above-mentioned information, please feel free to
contact your local dealer for further clarification and comments.
FPI HAS NO CONTROL OVER THE INSTALLATION OF YOUR STOVE, FPI GRANTS NO WARRANTY IMPLIED
OR STATED FOR THE INSTALLATION OR MAINTENANCE OF YOUR STOVE. THEREFORE, FPI ASSUMES NO
RESPONSIBILITY FOR ANY CONSEQUENTIAL DAMAGE(S).
SAVE THIS INSTRUCTION MANUAL FOR FUTURE REFERENCE