Figure 7: GF40 Inlet and Outlet Location
EXHAUST
Base of unit to center of flue
10 in (251 mm)
Center of unit to center of flue
0 in (0 mm)
[at center of unit]
FRESH AIR INTAKE
Base of unit to center of intake
6 in (153 mm)
Center of unit to center of intake
2-1/4 in (53 mm)
IMPORTANT:
When attaching the exhaust venting system
to the unit or when joining vent sections three screws must
be used at each joint. If vented horizontally, joints shall be
made gas tight with aluminum foil duct tape. Heights may
change if leveling legs are adjusted.
o
utSIDe
f
reSh
a
Ir
c
onnectIon
Outside fresh air is mandatory when installing this unit in
airtight homes (R2000) and mobile homes.
A Fresh-air intake is strongly recommended for all
installations
. Failure to install a fresh air intake may result
in improper combustion as well as the unit smoking during
power failures.
When connecting to an outside fresh air source, do not use
plastic or combustible pipe. A 2” minimum (51 mm) ID (inside
diameter) steel, aluminum or copper pipe should be used. It is
recommended, when you are installing a fresh air system, to keep
the number of bends in the pipe to a minimum.
2" ID
(51 mm)
Optional
Elbow
Outside
Wall
Figure 6: Outside Air Connection
GF40 Freestanding Pellet Stove |
15
15
|