Pellet burner GP xx sc 35
Incorrect operation of
the burner’s photic
sensor,
which
monitors the burning
process
The photic sensor for monitoring of the burning
process has to be re-adjusted or replaced – to be
performed by a servicing specialist.
8.
The burner does not
start or stops during
operation
No power supply
Check the operation of the burner’s display panel
and its indications.
Check the working order of the power supply of
the appliance, to which the burner is mounted
and which provides voltage with parameters
220V, 50Hz – to be performed by servicing
technician.
Check the burner’s electrical connections,
according to the attached wiring diagram. Check
for loose electrical connections – to be performed
by servicing technician.
No starting signal
submitted to the
burner
Check if the burner receives starting signal and
the working orders of the electrical connections of
the burner’s module, which submits signal for
operation – to be performed by servicing
technician;
Check for loose electrical connections.
Check the working order of the burner’s control
module, which provides voltage with parameters
220V, 50Hz – to be performed by servicing
technician.
The burner does not
operate, although
there is starting
signal
Check for activated alarm – check the list with
alarm codes in the controller and their indications,
as presented in the next table.
Blown fuses
To be performed by servicing technician:
check the fuses condition and if necessary
replace them with new fuses, but only from the
same type.
9.
The flame from the
burning process is
dim and the chimney
smokes too much.
Pellets with low
quality
Change the pellets as their water content is
probably higher than the required for normal
operation.
Improper adjustment
of the pellet burner’s
operational
parameters
Re-adjust the burner’s operational parameters –
to be performed by a servicing specialist.
10.
The burner starts,
but can’t transit to
stable
operation
mode
Improperly oriented
photic sensor
Change
the
photic
sensor’s
position
for
monitoring of the burning process by turning it
around its longitudinal axis.
The photic sensor’s
surface is dirty
Clean the contaminations (dirt) from the photic
sensor carefully.
The photic sensor
has defected – its
surface seems to be
burned
Replace the photic sensor with new one – ask for
servicing assistance.
11.
The burner operates
unstable
Malfunction of the
photic sensor
Check the photic sensor’s working order
The control module’s
operational
parameters have
been changed
Check
the
burner’s
heating
output
level
adjustment.
Check the controller’s adjustments – to be
performed by servicing technician.
12.
Heating of the pellet
burner’s fuel feeding
inlet pipe
Insufficient chimney
draught or not
cleaned burner
Clean the appliance and eventually the chimney.
Possible solution is to install additional flue gas
extraction fan and/or to change the chimney*.
13.
Heating of the pellet
Low chimney draught Clean the appliance and eventually the chimney.