![GreenEcoTherm GP 18 sc Installation, Operation And Maintenance Manual Download Page 25](http://html1.mh-extra.com/html/greenecotherm/gp-18-sc/gp-18-sc_installation-operation-and-maintenance-manual_2261585025.webp)
Pellet burner GP xx sc 25
Table 6.1. Heating output of a pellet burner from series “GP xx sc”, depending on the heating
output level.
PARAMETER
DIMENSION
VALUE
Model
-
GP 20_18 sc
GP 25 sc
GP 32 sc
Heating output level
kW
-
-
-
1
kW
7.0
7.0
10.0
2
kW
10.0
15.0
20.0
3
kW
15.0
20.0
25.0
4
kW
18.0
25.0
32.0
5
kW
20.0
28.0
35.0
It is recommended to operate the burner up to 4
th
level - including, as the 5
th
level
should be used exceptionally, but only for short periods of time.
To enter the menu ”EFFECT LEVEL” press the button under ENTER – “S”. To switch to
another menu press the button “+” under the arrow on the display. The button “ESC” is used
to exit the menu and to return to the main menu. When entering the menu ”EFFECT
LEVEL” the user can choose one of the 5 levels of heating output for operation of the
burner.
Figure 6.10. Choice of heating output level of a pellet burner from series “GP xx sc”.
Through the buttons “+” and “–” choose the desired heating output level of the
burner. After that press the button “S” to confirm the changes. To exit the menu
press the button “ESC”.
S
_
+
ESC
Effect level
[n]
O:5
N:5