83
U-Match Series DC
Inverter Service Manual
ƹ
E2 Freeze Protection
Freeze protection is normal protection but not abnormal malfunction. If freeze protection occurs frequently
GXULQJRSHUDWLRQSOHDVHFKHFNLIWKHLQGRRU¿OWHULVZLWK¿OWKEORFNDJHRULIWKHLQGRRUDLURXWOHWLVDEQRUPDO7KH
XVHULVUHTXLUHGWRFOHDQWKH¿OWHUFKHFNWKHDLURXWOHWDQGDLUUHWXUQSLSHSHULRGLFDOO\WRHQVXUHVPRRWKDLUUHWXUQ
and air outlet.
ƹ
E3 stands for three statuses:
(1). Low pressure protection (48K\60K);
(2). Refrigerant lacking protection;
(3). Refrigerant recycling mode;
ķ
If enter refrigerant recycling mode through special operation, the displayed E3 is not an error code. It
will be eliminated when exiting refrigerant recycling mode.
ĸ
If you do not want to have refrigerant lacking protection, you can enter the debugging mode through
wired controller and then cancel the refrigerant lacking protection mode.
E3 protection
Check if the
system low
pressure is lower
than 0.05MPa
No
Yes
Charge
refrigerant
according to the
requirement and
then turn on the unit
to see if E3
protection still
occurs
Yes
Enter
debugging mode
through wired
controller and select
without refrigerant
lacking protection; then
turn on the unit to see
if E3 protection still
occurs
No
Completely open the liquid
valve and gas valve of outdoor
unit
Check if the liquid
valve and gas
valve of outdoor
unit open
completely
Yes
Yes
Yes
Weld the leakage point and
recharge refrigerant after
vacuum pumping and pressure
retaining are passed
Check if there is
leakage in the
pipeline
Reconnect wire according to
the circuit diagram or replace
the pressure switch
Yes
09K~42K outdoor units
are without low pressure switch and
check if the wiring of mainboard is
normal; 48K~60K outdoor units are
with low pressure switch and
check if the low pressure
switch and its wiring
are normal
Replace the outdoor main
control board
No
Summary of Contents for U-MATCH IV SERIES
Page 1: ...T1 R410A 50Hz GC201304 U MATCH SERIES DC INVERTERAIR CONDITIONERS SERVICE MANUAL...
Page 4: ...1 U Match Series DC Inverter Service Manual PRODUCT QSPEVDU...
Page 19: ...16 U Match Series DC Inverter Service Manual QSPEVDU 4 PIPING DIAGRAM...
Page 20: ...17 U Match Series DC Inverter Service Manual CONTROL DPOUSPM...
Page 22: ...19 U Match Series DC Inverter Service Manual DPOUSPM 1 2 Heating Operation...
Page 50: ...47 U Match Series DC Inverter Service Manual INSTALLATION...
Page 80: ...77 U Match Series DC Inverter Service Manual 7KUHH SKDVH a L1 L2 L3 N 1 2 LJXUH...
Page 81: ...78 U Match Series DC Inverter Service Manual MAINTENANCE...
Page 106: ...103 U Match Series DC Inverter Service Manual Model GUHD36NK3FO Model GUHD42NK3FO 0 0...
Page 164: ...JF00301816...