11
U-Match Series DC
Inverter Service Manual
QSPEVDU
3.1.3 Floor-ceiling Type
Model
Indoor unit
GTH09K3FI
GTH12K3FI
GTH18K3FI
GTH24K3FI
Product Code
ED020N0650
ED020N0660
ED020N0670
ED020N0680
Outdoor unit
GUHD09NK3FO
GUHD12NK3FO
GUHD18NK3FO
GUHD24NK3FO
Product Code
CF090W0630
CF090W0640
CF090W0650
CF090W0660
Capacity
Cooling Capacity
kW
2.7(0.80-3.50)
3.5(0.90-3.90)
5.0(1.60-5.80)
7.0(2.40-8.20)
Heating Capacity
kW
2.9(0.80-3.80)
3.8(0.90-4.10)
5.6(1.40-6.80)
8.0(2.40-9.00)
PdesignH
kW
2.9
3.0
4.5
7.0
Power Input
Cooling
kW
0.84(0.20-1.28)
1.09(0.26-1.40)
1.55(0.55-1.75)
2.18(0.85-2.50)
Heating
kW
0.80(0.20-1.20)
1.05(0.22-1.20)
1.55(0.50-1.90)
2.21(0.80-2.75)
Design load
Average
SEER / SCOP
W/W
5.1/3.8
5.1/3.8
5.1/3.8
5.1/3.8
Energy Rate(Cooling / Heating)
A/A
A/A
A/A
A/A
Indoor Unit
GTH09K3FI
GTH12K3FI
GTH18K3FI
GTH24K3FI
Power Supply
220-240V~ 50Hz
Heat Exchange
Cross Fin Coil
Cross Fin Coil
Cross Fin Coil
Cross Fin Coil
Fan
Drive
direct
direct
direct
direct
Motor Output
kW
0.015×1
0.02×1
0.04×1
0.065×1
Air Flow
m
3
/h
600
700
1000
1200
Sound Pressure Level(H/M/L)
dB(A)
37/35/32/28
40/38/35/31
44/42/38/32
49/48/46/40
Air Filter
Standard washable synthetic
Drain Piping
mm
ĭî
ĭî
ĭî
ĭî
Outline Dimensions (W×H×D)
mm
1220×225×700
1220×225×700
1220×225×700
1220×225×700
Net Weight
kg
38
39
39
40
Outdoor Unit
GUHD09NK3FO
GUHD12NK3FO
GUHD18NK3FO
GUHD24NK3FO
Power Supply
220-240V~ 50Hz
Heat Exchange
Cross Fin Coil
Compressor
Type
Rotary
Rotary
Rotary
Rotary
Power Input
W
942
942
1440
2550
Refrigerant
Control
Electronic Expansion Valve
Charge
kg
1.2
1.2
1.4
2.2
Outline Dimensions (W×H×D)
mm
848×540×320
848×540×320
955×700×396
980×790×427
Net Weight
kg
35
35
47
67
Piping Connections
Liquid
Inch
ĭ
ĭ
ĭ
ĭ
Gas
Inch
ĭ
ĭ
ĭ
ĭ
Max. Length
m
20
20
20
30
Max. Height
m
15
15
15
15
Summary of Contents for U-MATCH IV SERIES
Page 1: ...T1 R410A 50Hz GC201304 U MATCH SERIES DC INVERTERAIR CONDITIONERS SERVICE MANUAL...
Page 4: ...1 U Match Series DC Inverter Service Manual PRODUCT QSPEVDU...
Page 19: ...16 U Match Series DC Inverter Service Manual QSPEVDU 4 PIPING DIAGRAM...
Page 20: ...17 U Match Series DC Inverter Service Manual CONTROL DPOUSPM...
Page 22: ...19 U Match Series DC Inverter Service Manual DPOUSPM 1 2 Heating Operation...
Page 50: ...47 U Match Series DC Inverter Service Manual INSTALLATION...
Page 80: ...77 U Match Series DC Inverter Service Manual 7KUHH SKDVH a L1 L2 L3 N 1 2 LJXUH...
Page 81: ...78 U Match Series DC Inverter Service Manual MAINTENANCE...
Page 106: ...103 U Match Series DC Inverter Service Manual Model GUHD36NK3FO Model GUHD42NK3FO 0 0...
Page 164: ...JF00301816...