U-Match Series DC
Inverter Service Manual
QSPEVDU
3.3.2 Indoor unit
Table 1-4-2 Electrical Data of Indoor Unit
Model
Power Supply
Fan Motor FLA
Fuse/Breaker
Capacity
Min. Power
Supply Cord
V/Ph/Hz
A
A
mm
2
GFH09K3FI
220-240,1,50
<1
5/6
1.0
GFH12K3FI
220-240,1,50
<1
5/6
1.0
GFH18K3FI
220-240,1,50
<1
5/6
1.0
GFH24K3FI
220-240,1,50
<1
5/6
1.0
GFH30K3FI
220-240,1,50
<1
5/6
1.0
GFH36K3FI
220-240,1,50
<1
5/6
1.0
GFH42K3FI
220-240,1,50
<1
5/6
1.0
GFH48K3FI
220-240,1,50
<1
5/6
1.0
GFH60K3FI
220-240,1,50
<1
5/6
1.0
GKH12K3FI
220-240,1,50
<1
5/6
1.0
GKH18K3FI
220-240,1,50
<1
5/6
1.0
GKH24K3FI
220-240,1,50
<1
5/6
1.0
GKH30K3FI
220-240,1,50
<1
5/6
1.0
GKH36K3FI
220-240,1,50
<1
5/6
1.0
GKH42K3FI
220-240,1,50
<1
5/6
1.0
GKH48K3FI
220-240,1,50
<1
5/6
1.0
GKH60K3FI
220-240,1,50
<1
5/6
1.0
GTH09K3FI
220-240,1,50
<1
5/6
1.0
GTH12K3FI
220-240,1,50
<1
5/6
1.0
GTH18K3FI
220-240,1,50
<1
5/6
1.0
GTH24K3FI
220-240,1,50
<1
5/6
1.0
GTH30K3FI
220-240,1,50
<1
5/6
1.0
GTH36K3FI
220-240,1,50
<1
5/6
1.0
GTH42K3FI
220-240,1,50
<1
5/6
1.0
GTH48K3FI
220-240,1,50
<1
5/6
1.0
GTH60K3FI
220-240,1,50
<1
5/6
1.0
Notes:
RLA:Rated load amperes
LRA:Locked rotor amperes
FLA:Full load current
ķ
Install the disconnect device with a contact gap of at least 3mm in all poles nearby the units (Both indoor
unit and outdoor unit).The appliance must be positioned so that the plug is accessible.
ĸ
7KHVSHFL¿FDWLRQVRIWKHEUHDNHUDQGSRZHUFDEOHOLVWHGLQWKHWDEOHDERYHDUHGHWHUPLQHGEDVHGRQWKH
maximum power (maximum amps) of the unit.
Ĺ
7KHVSHFL¿FDWLRQVRIWKHSRZHUFDEOHOLVWHGLQWKHWDEOHDERYHDUHDSSOLHGWRWKHFRQGXLWJXDUGHGPXOWL
wire copper cable (like, YJV copper cable, consisting of PE insulated wires and a PVC cable jacket) used at
ɋDQGUHVLVWLEOHWRɋVHH,(&,IWKHZRUNLQJFRQGLWLRQFKDQJHVWKH\VKRXOGEHPRGL¿HG
according to the related national standard.
ĺ
The specifications of the breaker listed in the table above are applied to the breaker with the working
WHPSHUDWXUHDWɋ,IWKHZRUNLQJFRQGLWLRQFKDQJHVWKH\VKRXOGEHPRGL¿HGDFFRUGLQJWRWKHUHODWHG
national standard.
Summary of Contents for U-MATCH IV SERIES
Page 1: ...T1 R410A 50Hz GC201304 U MATCH SERIES DC INVERTERAIR CONDITIONERS SERVICE MANUAL...
Page 4: ...1 U Match Series DC Inverter Service Manual PRODUCT QSPEVDU...
Page 19: ...16 U Match Series DC Inverter Service Manual QSPEVDU 4 PIPING DIAGRAM...
Page 20: ...17 U Match Series DC Inverter Service Manual CONTROL DPOUSPM...
Page 22: ...19 U Match Series DC Inverter Service Manual DPOUSPM 1 2 Heating Operation...
Page 50: ...47 U Match Series DC Inverter Service Manual INSTALLATION...
Page 80: ...77 U Match Series DC Inverter Service Manual 7KUHH SKDVH a L1 L2 L3 N 1 2 LJXUH...
Page 81: ...78 U Match Series DC Inverter Service Manual MAINTENANCE...
Page 106: ...103 U Match Series DC Inverter Service Manual Model GUHD36NK3FO Model GUHD42NK3FO 0 0...
Page 164: ...JF00301816...