45
U-Match Series DC
Inverter Service Manual
DPOUSPM
(3). Setting method:
Do not need to set this function
Notes:
ķ
The interface voltage should be 220V AC intense current;
ĸ
If malfunction light is connected, please make sure its power is not too big (it should be within 10W),
otherwise, the relay on mainboard will be burnt.
Figure 2-7-16
Table 2-7-4 Corresponding interfaces of mainboard
No.
Interface
1
Evaporator temperature sensor
2
Swing motor
3
Human sensitive
4
Door control
5
Full water detection
6
Interface of light board
7
Communication port of centralized controller
8
MOUDBUS interface
9
Interface of annunciator live wire
10
ON interface of fresh air valve
11
OFF interface of fresh air valve
12
Interface of annunciator neutral wire
13
Interface of DC motor
14
Mainboard grounding wire
15
Power live wire
16
Power neutral wire
17
Neutral wire of fresh air valve
18
Water pump interface
19
Live wire of fresh air valve
20
Interface of anion generator
21
Interface of auxiliary heating board
22
Interface of outdoor unit
23
Interface of wired controller
24
Monitor interface
25
Ambient temperature sensor
Summary of Contents for U-MATCH IV SERIES
Page 1: ...T1 R410A 50Hz GC201304 U MATCH SERIES DC INVERTERAIR CONDITIONERS SERVICE MANUAL...
Page 4: ...1 U Match Series DC Inverter Service Manual PRODUCT QSPEVDU...
Page 19: ...16 U Match Series DC Inverter Service Manual QSPEVDU 4 PIPING DIAGRAM...
Page 20: ...17 U Match Series DC Inverter Service Manual CONTROL DPOUSPM...
Page 22: ...19 U Match Series DC Inverter Service Manual DPOUSPM 1 2 Heating Operation...
Page 50: ...47 U Match Series DC Inverter Service Manual INSTALLATION...
Page 80: ...77 U Match Series DC Inverter Service Manual 7KUHH SKDVH a L1 L2 L3 N 1 2 LJXUH...
Page 81: ...78 U Match Series DC Inverter Service Manual MAINTENANCE...
Page 106: ...103 U Match Series DC Inverter Service Manual Model GUHD36NK3FO Model GUHD42NK3FO 0 0...
Page 164: ...JF00301816...