24
(11) I FEEL Function(reserved)
When I FEEL command is received and controller has received the ambient temperature sent by remote controller, the
controller will operate at the temperature sent by remote controller (For cold air prevention, the unit operates accord-
ing to the ambient temperature sensed by the air conditioner). If it only received I FEEL command and hasn’t received
the valid ambient temperature, air conditioner will operate according to the ambient temperature sensed by itself. Re-
mote controller will send the ambient temperature to controller every 10min. If controller hasn’t received the ambient
temperature sent by remote controller for 11min, air conditioner will operate according to the ambient
temperature sensed y itself. If I FEEl hasn’t been set, ambient temperature will adopt the temperature sensed by air
conditioner. Controller displays I FEEL ambient temperature 34°F~138°F.
(12) Health, Cold Plasma Function(reserved)
At ON status, press health button (if there isn’t health button on remote controller, health function is ON in default)
on remote controller can set health or cold plasma function. Health or cold plasma function can operate when it set
ON and indoor fan operates.
(13) Fahrenheit Display Function
Niexie tube displays current set temperature. If the remote control signal is Fahrenheit, the temperature will be display
by Fahrenheit. Set temperature range is 61~86°F. Under auto mode, nixie tube displays 77°F in cooling and fan, and
68°F in heating. Cooling only controller
only displays 77°F.
(14) Locked Protection to Indoor Fan
If the indoor fan motor keeps low rotation speed for a continuous period of time after startup, the unit will stop opera-
tion and display“H6”.
(15) Compulsory Defrosting Function
When the outdoor environment is formidable, such as temperature is too low and humidity is too high, and there
is too much frost in outdoor unit which affect the heating effect, users can select compulsory defrosting function to
outdoor unit’s heating effect. on method:
When the unit is turned on in heating mode by remote controller and the set temperature is 61°F, press “+,-,+,-,+,-”
buttons for 5s successively, indoor unit will enter into compulsory defrosting setting and send the compulsory defrost-
ing mode signal to outdoor unit and then outdoor unit will enter into compulsory defrosting mode.
Product Introduction
Basic Functions - 9K & 12K 115 volt