182
Disassembly of Outdoor Unit
18K 240 volt unit
Warning - Wait 10 minutes after power is disconnected before starting disassembly
.
Remove the soundproof sponge wrapping the com-
pressor
Remove screws attached to the isolation sheet and
then remove the isolation sheet
7. Remove isolation sheet
Remove the screws attached to the gas valve and
unsolder the welding joint between the gas valve
and the air-return pipe to remove the gas valve
(NOTE: Discharge the refrigerant completely be-
fore un-soldering; When un-soldering, wrap the gas
valve with a wet cloth completely to avoid damage
to the valve cause by high temperature). Remove
the screws attached to the liquid valve and unsolder
the welding joint connecting the liquid valve to the
Y-type pipe to remove the liquid valve.
8. Remove gas and liquid valve
6. Remove sound proof sponge