167
Disassembly of Neo Outdoor Unit
115v model, Other models may vary slightly
Warning - Wait 10 minutes after power is disconnected before starting disassembly
.
Unscrew the fastening nut of the 4-way valve as-
sembly coil and remove the coil. Wrap the 4-way
valve assembly with wet cotton and unsolder the
four weld spots connecting the 4-way valve assem-
bly to take it out (Note: Refrigerant should be dis-
charged first). Welding process should be as quickly
as possible and keep wrapping wet cotton all the
time. Be sure not to burn out the lead-out wire of
compressor.
Remove the three footing screws of the compressor
and remove the compressor
10. Remove 4-way valve assembly
11 Remove compressor