173
Disassembly of Outdoor Unit
9K 240 volt unit
Warning - Wait 10 minutes after power is disconnected before starting disassembly
.
Remove the nut attached to the blade and then
remove the axial flow blade
Remove the four tapping screws attached to the
motor. Pull out the lead wire and remove the motor.
Remove the two tapping screws attached to the mo-
tor support. Lift motor support to remove it.
7. Remove axial flow blade
8. Remove motor and support assy
Remove the two screws attached to the cover of the
electric box. Lift to remove the cover. Loosen the
wire and disconnect the terminal. Lift to remove
the electric box assembly.
9. Remove electric box assy