188
Disassembly of Outdoor Unit
24K 240 volt unit
Warning - Wait 10 minutes after power is disconnected before starting disassembly
.
Remove the 2 bolts holding the valve sub-assy.
Unsolder joint between gas valve and return pipe,
then remove the gas line. (NOTE: Discharge the
refrigerant completely before un-soldering; When
un-soldering, wrap the gas valve with a wet cloth
completely to avoid damage to the valve cause by
high temperature). Remove the screws attached to
the liquid valve and unsolder the welding joint con-
necting the liquid valve to the Y-type pipe to remove
the liquid valve.
Remove the three nuts on the compressor feet, then
remove the compressor.
12. Remove compressor
Remove the screws connecting the left side plate
and chassis, then remove the left side plate.
13. Remove left side plate
11. Remove gas and liquid valve