168
Disassembly of Indoor Unit
9K 240 volt unit, models may vary slightly
Warning - Wait 10 minutes after power is disconnected before starting disassembly
.
Open the front panel. Push the rotor shaft on both
sides of the panel to make it separate from the
groove. Remove the panel.
Loosen the clasp of the filter. Push the filter inward
and then draw it upward to remove it.
Remove axial sleeve of horizontal louver. Bend the
louver outwards and then remove the louver.
Loosen the screws of the electric box cover ‘2” with
screwdriver. Remove the electric box cover “2.”
Open the screw cap on the front case. Remove the
screws fixing the front case. Loosen the six clasps of
the front case. Remove the front case.
1. Remove Panel
2. Remove filter
3. Remove horizontal louver and front case