177
Disassembly of Outdoor Unit
12K 240 volt unit
Warning - Wait 10 minutes after power is disconnected before starting disassembly
.
Remove screws attached to reactor and then re-
move the reactor.
Remove screws attached to the isolation sheet and
then remove the isolation sheet
Discharge the refrigerant completely; unsolder the
pipeline connecting the compressor and the con-
denser assembly, and then remove the 4-way valve
assembly.
5. Remove the reactor and isolation sheet
6. Remove f4-way valve assy and condenser