183
Disassembly of Outdoor Unit
18K 240 volt unit
Warning - Wait 10 minutes after power is disconnected before starting disassembly
.
Discharge the refrigerant completely; unsolder the
pipeline connecting the compressor and the con-
denser assembly, and then remove the 4-way valve.
Remove the nuts on the compressor feet and then
remove the compressor.
10. Remove compressor
Remove the four tapping screws attached to the
motor. Pull out the lead wire and remove the motor.
Remove the two tapping screws attached to the mo-
tor support. Lift motor support to remove it.
11. Remove motor and motor support
9. Remove 4-way valve