GREE AIR SOURCE HEAT PUMP WATER HEATER SERVICE MANUAL
3
2 NOMENCLATURE
GRS
-
1.5
/
T
D
200
A
Nb
A
-
K
1
2
3
4
5
6
7
8
9
10 11
12
13
14
15
No.
Description
Options
1
Product code
GRS
—heat pump water heater
2
Heating capacity code Nominal heating capacity (Unit: kW)
3
Compressor system
Null for single compressor; S
—two compressors
4
Functions 1
P
— inverter; Pd—DC inverter; M—modular for fixed speed; PM—AC
inverter modular; PdM
—DC inverter modular; Null for fixed speed
5
Functions 2
Null for general; Re
—Low temp heat pump
6
Material of water tank Null for stainless steel; T
—Porcelain enamel
7
Function code
Null for no electric heating function; D
—with electric heating function
8
Water tank capacity
Capacity of water tank; Unit:
(
L
)
9
Design code
A
—LCJW: floor standing type; outer coil pipe static heating type;
B
—BCJW: wall-mounted type; outer coil pipe static heating type;
C
—LCJ: floor standing type; built-in coil pipe static heating type;
D
—BCJ: wall-mounted type; built-in coil pipe static heating type;
10
Water tank shape
Null for rotundity; F
—squareness
11
Inner tank number
Null for one inner tank; 2
—two inner tank
12
Refrigerant
Null for R22; R407c
—N; R410A—Na; R134a—Nb; R417A—Ne
13
Design Serial number A, B,
C…or A1, A2…, B1, B2…
14
Cycle function
H
—cycle function; Null for no cycle function
15
Power supply code
M
—380-415V 3PH~50Hz; K—220V-240V 1PH~50Hz;
D
—220V-240V 1PH~60Hz; …
3 FUNCTION
No.
Name
Function
1
Compressor
Increases pressure for the refrigerant and provides driving force for
circular flow of the refrigerant as a main driving component.
2
Four-way valve
Reverses flow direction of the refrigerant when the system
switches between the normal heat up mode and defrosting mode.
3
Water tank
Provides heat exchange channel for refrigerant and water and
stores hot water for daily use.
4
Electronic expansion
valve
Speeds up high-pressure and high-temperature refrigerant and
reduces pressure and adjusts the circulation amount of coolant.
5
Finned tube
exchanger
Provides heat exchange channel for refrigerant and air.
6
Fan motor
Enhances heat exchange on the air side of the finned tube
exchange and provides a low-temperature heat source
continuously.
7
Filter
Filters impurities in refrigerant to protect components with small
diameter.
Summary of Contents for GRS-1.5/D150ANbA-K
Page 3: ...GREE AIR SOURCE HEAT PUMP WATER HEATER SERVICE MANUAL 1 PRODUCT ...
Page 11: ...GREE AIR SOURCE HEAT PUMP WATER HEATER SERVICE MANUAL 9 CONTROL ...
Page 25: ...GREE AIR SOURCE HEAT PUMP WATER HEATER SERVICE MANUAL 23 INSTALLATION ...
Page 47: ...GREE AIR SOURCE HEAT PUMP WATER HEATER SERVICE MANUAL 45 COMMISSIONING and TRIAL RUN ...
Page 55: ...GREE AIR SOURCE HEAT PUMP WATER HEATER SERVICE MANUAL 53 MAINTENANCE ...
Page 70: ...GREE AIR SOURCE HEAT PUMP WATER HEATER SERVICE MANUAL 68 UNIT MAINTENANCE ...
Page 81: ...JF00303641 ...