GREE AIR SOURCE HEAT PUMP WATER HEATER SERVICE MANUAL
35
is recommended, d etailed list is as follows:
Material code
Name
Quantity
76612816
Selflimiting temperature tracing belt
1
01802894
frame
1
8600800101
aluminum-foil paper
1
64132820
Pipeline antifreezing tracing belt installation statement sheet
1
(6) Installation of Stabilizing valve
Before connecting water pipe, measure water supply pressure of running water first, if water pressure
is over 0.7MPa, add stabilizing valve in waterway, otherwise, pressure relief on safety valve might occur
when the unit is not heated. Stabilizing valve (―→‖ direction shall accord with the water tank direction) shall
be installed between safety valve and filter.
Notices
!
①
To ensure water safety, the PPR pipe length at the water inlet and outlet is determined as per the
formula: L
≥
70×R
2
, wherein L indicate the pipe length, and R indicates the inner diameter of the pipe (unit:
cm). The pipe should be insulated properly. No metal pipe is allowed.
②
To ensure safety and reliability, special accessory equipped with this unit must be adopted (PPR
water pipe joint, safety valve and filter etc.). Don't use the accessory of any third party and replace the
accessory by yourself, any losses thereof for normal operation and usage of heat pump water heater
result from personal injury and improper installation, Gree shall not be liable.
Summary of Contents for GRS-1.5/D150ANbA-K
Page 3: ...GREE AIR SOURCE HEAT PUMP WATER HEATER SERVICE MANUAL 1 PRODUCT ...
Page 11: ...GREE AIR SOURCE HEAT PUMP WATER HEATER SERVICE MANUAL 9 CONTROL ...
Page 25: ...GREE AIR SOURCE HEAT PUMP WATER HEATER SERVICE MANUAL 23 INSTALLATION ...
Page 47: ...GREE AIR SOURCE HEAT PUMP WATER HEATER SERVICE MANUAL 45 COMMISSIONING and TRIAL RUN ...
Page 55: ...GREE AIR SOURCE HEAT PUMP WATER HEATER SERVICE MANUAL 53 MAINTENANCE ...
Page 70: ...GREE AIR SOURCE HEAT PUMP WATER HEATER SERVICE MANUAL 68 UNIT MAINTENANCE ...
Page 81: ...JF00303641 ...