YP4025A-48TR20
Troubleshooting
105
2019-03-19
411-198M
Auxiliary
Hydraulics
Inoperative
Marker/Fold switch set to Fold
CFM Switch must be set to “Marker” for Aux to function. Set tractor
remote circuit to Neutral or Float before switching.
Marker/Aux valve set to Marker
Selector valve must be set to Aux. Set tractor remote circuit to
Neutral or Float before changing valve.
Hydraulic
Hitch Won’t
Stay Raised
Bypass valve is open at hitch
Close valve.
Speed Reading
Doesn’t Match
Tractor
Monitor speed reading will only match
tractor with implement name lowered
If speeds don’t agree during planting (with implement name
lowered), re-calibrate radar speed sensor with implement name
lowered. See page 169.
General Troubleshooting
Problem
Cause
Solution