33
M_LS900 Fibre - LS900 Edge_EN_C
Connections - Installation
Input / Output characteristics (Sub-D15 connector)
Number
Function
Type
Comments
1
O1
Output NPN
Maximum current: 50 mA
2
O2
Output NPN
Maximum current: 50 mA
3
O3
Output NPN
Maximum current: 50 mA
4
O4
Output NPN
Maximum current: 50 mA
5
5 V
Available for powering the loads
switched by the NPN outputs (O1 -
O4)
Maximum current: 200 mA
6
I1
Dry contact
Input
TTL-compatible
7
I3
Dry contact
Input
TTL-compatible
8
Gnd
Grounding
The grounds are shared by pins
8-11-12-13.
9
24 V
Available for powering the loads
switched by the NPN outputs (O1 -
O4)
Maximum current: 100 mA
10
Maximum current: 100 mA
11
Gnd
Grounding
The grounds are shared by pins
8-11-12-13.
12
13
14
I2
Dry contact
Input
TTL-compatible
15
I4
Dry contact
Input
TTL-compatible
Note: The loads switched by the NPN outputs can be powered by 5 V / 24 V.
Wiring example -
Wiring example -
24 V inductive load
5 V inductive load