8-001 Gap Between the Drawer Front and Zargen Slide
Possible Reasons > Solving the Problem
- The front bore holes are not drilled deeply enough. The dowels stand out from the base of the bore hole. > Drill
the bore holes deeper.
- The front bore holes are not the in correct position. Space the bore holes correctly from one another.
- The front bore holes are not in the correct position. > Set the front stops.
- The drawer bottom is too long > Correct drawer bottom according to Section 7-001.
- The back wall is too thick. > Set the back wall thickness according to Section 7-010.
- The set gap „A“ on Section 7-010 is too large. > Correct according to Section 7-010.
- The drawer bottom is too thick; the compression slides don’t move to the end. > Set the bottom
thickness according to Section 7-011.
- The size for the bottom groove 12 mm is too large; the machine doesn’t have enough force to move
both Zargen slides lengthwise into the bottom groove. > The specified size should comply with
Section 7-001-04 and 7-001-05.
- The depth of the bottom groove is insufficient; the machine can’t move both Zargen slides lengthwise into
the bottom groove. > Make the grooves deeper.
8-002 Gap Between the Drawer Bottom and Bottom Support with the Zargen Slide
Possible Reasons > Solving the Problem
- The bottom groove is not deep enough; the machine can press both Zargen slides lengthwise into the
drawer bottom. > Make the bottom groove deeper.
- The drawer bottom is too thin. ( The change-over insert is too far away.) > Set the bottom thickness
according to Section 7-001. Deviations from the given dimensions may be necessary.
- The size for the bottom groove 12 mm is too large; the machine can’t press both Zarge slides
lengthwise into the bottom groove. > The specified size should comply with Point 7-001-04 and 7-001-05.
- The bevels are missing underneath the bottom. > Attach bevel.
8-003 Gap Between the Drawer Bottom and the Drawer Back Wall
Possible Reasons > Solving the Problem
- The drawer bottom is too short. > Comply with the dimensions in Section 7-001.
- The drawer back wall is too thin. > Set according to Section 7-010.
8-004 Gap Between the Zargen Slide and Back Wall Inside the Drawer
Possible Reasons > Solving the Problem
- The back wall bore holes are not in the correct position. > Correct the spacing of the bore holes.
Specified size = 12+0.3 mm, Ideal size 12.2 to 12.3 mm
- The insert screws for the back wall dowels are not set correctly. > Back out the screws more.
8. TROUBLE SHOOTING AND PROBLEM SOLVING
The star in your cabinet
34
Summary of Contents for ZPM
Page 1: ...The star in your cabinet Grass ZPM O P E R AT I N G I N S T R U C T I O N S ...
Page 12: ...4 DESCRIPTION OF MACHINE COMPONENTS The star in your cabinet 12 Illustration 4 001 01 ...
Page 24: ...Illustration 7 002 01 Illustration 7 003 01 7 OPERATING THE ZPM The star in your cabinet 24 ...
Page 26: ...Illustration 7 006 01 Illustration 7 007 01 7 OPERATING THE ZPM The star in your cabinet 26 ...
Page 30: ...Illustration 7 010 01 Illustration 7 011 01 7 OPERATING THE ZPM The star in your cabinet 30 ...
Page 32: ...Illustration 7 012 01 7 OPERATING THE ZPM The star in your cabinet 32 ...