99
Kahuna
Installation Manual
Mav Remote Specifications
Mainframe Power Supplies
Mainframes
11RU Mainframe
6RU Mainframe
Two fully independent hot-swappable PSU modules, with separate mains power
feeds via 2 x 16A IEC-C20 socket. Dual Redundant requires two more fully
independent PSU modules; with separate mains power feeds via 2 x 16A IEC
socket.
Two fully independent hot-swappable PSU modules, with separate mains power
feeds via 2 x 16A IEC-C20 socket. Redundancy provided by the second PSU.
Mav Remote
Connector
Description
Video Output
1x Monitor Output
USB
2x USB 2 Connectors
Network
2x 10/100/1000 base T, Auto - MDX/MDXI on RJ45 connectors
Connections to
MAV modules
8x RJ45 connectors for Comms and 2x +12V 0.42A power supply
Connection to other MAV modules
These are
NOT
Ethernet, connections must be direct to MAV modules.
Do Not
use network switches or hubs.
CAT5 or above cables - crossover cables are
Not
suitable.
Mav Remote Power Supplies
Power Supply
Description
To the
Mav Remote
2x Fully independent external PSU modules with separate mains power feeds via
2x 10A IEC leads.
Output from each PSU = 12V DC 100W via Kycon KPPX 4 Pin or Compatible
connectors to the Mav Remote.
2 supplied as standard per Mav Remote, One PSU provides Dual Redundancy.
Mav Remote External Mains Power Supply Requirements
Voltage
100V - 240V 50/60Hz
Power
Less than 100Watts (per MAV-GU Remote)