2.2 Detergent and rinse aid
2 Installation
2.2
Detergent and rinse aid
NOTE
Only pre drilled hole and connections must be used for sensor, detergent
and rinse aid.
The dosing equipment is only to be connected in the detergent connection
box.
All dosing equipment must be fitted with a main switch.
Do not use detergent containing chlor.
To obtain the best performance of this GRANULDISK pot washer we strongly recommend
installing sensor controlled detergent dosing equipment and appropriate rinse aid equipment.
Figure 3: Detergent and rinse aid junction box
The 230 V AC and the 24 V AC supply as well as the control signals for the detergent and
rinse aid equipment are located in the junction box behind the front cover plate. There are
terminal blocks as listed below in the junction box (Picture:
Figure 4 Detergent and rinse aid
).
The dosing of rinse aid is normally done during filling of the rinse tank, depending on rinse
aid this could cause foaming in the rinse tank causing error 112. To avoid this the rinse aid
dosing equipment could use the detergent signal and the equipment set to dose on time, if
possible (fixed volume on positive flank). This means the dosing of rinse aid is done when the
rinse tank is full and the foam is avoided.
14
Rev. 2012-05
Summary of Contents for Granule Maxi
Page 2: ......
Page 6: ...CE Declaration of Conformity ...
Page 13: ...2 Installation 2 1 Installation instructions Figure 2 Rev 2012 05 13 ...
Page 22: ...2 3 How to lay the Granule Maxi down on its side 2 Installation ...
Page 44: ...5 Routines for long time storage ...
Page 46: ...6 Warranty ...
Page 54: ...7 2 Service instructions 2 year service 7 Maintenance and Service ...
Page 57: ...8 Steam heating Granule Maxi 8 5 Connection Steam connections Rev 2012 05 57 ...
Page 59: ...8 Steam heating Granule Maxi 8 7 Diagrams 8 7 Diagrams Diagram 1 Diagram 2 Rev 2012 05 59 ...
Page 60: ...8 7 Diagrams 8 Steam heating Granule Maxi Diagram 3 Diagram 4 60 Rev 2012 05 ...
Page 62: ...9 Appendix This page intentionally left blank 62 Rev 2012 05 ...
Page 69: ...69 200 230 V 400 415 V CW ...
Page 70: ...70 200 230 V 400 415 V CW ...
Page 71: ...71 200 230 V 400 415 V CW ...
Page 72: ...72 200 230 V 400 415 V CW ...
Page 73: ...73 200 230 V 400 415 V CW ...
Page 74: ...74 200 230 V 400 415 V CW ...
Page 75: ...75 208 575 V CSA ...
Page 76: ...76 208 575 V CSA ...
Page 77: ...77 208 575 V CSA ...
Page 78: ...78 208 575 V CSA ...
Page 79: ...79 208 575 V CSA ...
Page 80: ...80 208 575 V CSA ...
Page 81: ...81 230 400 415 V Steam heated ...
Page 82: ...82 230 400 415 V Steam heated ...
Page 83: ...83 230 400 415 V Steam heated ...
Page 84: ...84 230 400 415 V Steam heated ...
Page 85: ...85 230 400 415 V Steam heated ...
Page 86: ...86 380 400 415 440 480 V ...
Page 87: ...87 380 400 415 440 480 V ...
Page 88: ...88 380 400 415 440 480 V ...
Page 89: ...89 380 400 415 440 480 V ...
Page 90: ...90 380 400 415 440 480 V ...
Page 91: ...91 380 400 415 440 480 V ...
Page 92: ...92 575 V CSA Steam heated ...
Page 93: ...93 575 V CSA Steam heated ...
Page 94: ...94 575 V CSA Steam heated ...
Page 95: ...95 575 V CSA Steam heated ...
Page 96: ...96 575 V CSA Steam heated ...
Page 97: ...97 575 V CSA Steam heated ...