Electrical System
Grand Soleil 43'
7.
5
12 Vdc Control Panel
It is located near the chart table on the right hand side and is divided
in sections described in English words. It includes all the 12 Vdc
functions, the voltmeter and the ammeter.
SERVICES
PUMPS
RUNNING LIGHTS
INSTRUMENTS
A
B
D
C
E
F
G
A
12 V DC VOLTMETER
by selecting manually the three ways selector near the chart table
seat, it indicates the voltage of each group of batteries: 1 for the
three service batteries, BOTH for all the four batteries together
and 2 for the engine's one.
- With engine and battery charger off, the instrument must
show at least 11.8 Volts. Should this figure drop below 11.2
Vdc, batteries should be immediately recharged. In any case
never let the voltage drop below 10.5 Vdc.
B
SERVICE CONSUMPTION
(Ammeter)
indicates the value of the 12 Vdc current flow both in discharge (if
any 12 Vdc appliance is on) or in charge (wheneither engine or
battery charger is on). When batteries are under charge, it will
show a figure that is the result of the positive value of the charge
minus the negative one of the consumption.
C
12 V DC
(12 Vdc socket)
D
SERVICES
(Group of switches for the Services)
E
PUMPS
(Group of switches for the Pumps)
F
RUNNING LIGHTS
(
Navigation Lights switches
)
G
INSTRUMENTS
(Electronic Instruments switches
)