Electro-pneumatic Control Panel Display Screens
Container
Container
Container Recipe
Recipe
Recipe Edit
Edit
Edit Screen
Screen
Screen
An empty tote is required for defining the container
recipe.
Icon/Field
Icon/Field
Icon/Field
Description
Description
Description
Recipe
Recipe
Recipe Name
Name
Name
User-defined alphanumeric field, 19 characters maximum.
Lock
Lock
Lock
When locked, the password defined on the System Settings page must be entered to
edit the selected recipe.
recipe not locked
recipe locked
Numeric displays next to the icons are the pressure settings defined in the current
recipe. Changes entered here are not saved to the recipe. A locked recipe will not
allow changing these settings.
Ram
Ram
Ram Control
Control
Control
Ram
Ram
Ram Up
Up
Up
Momentarily press to raise the ram assembly. The ram will continue raising until the
ram has reached the top of its travel, unless manually stopped.
Ram
Ram
Ram Hold
Hold
Hold
Momentarily press to keep the ram at the current location.
NOTE:
NOTE:
NOTE: This is an active hold and the system may momentarily energize Ram Up to
keep the platen from drifting. Active hold is enabled for 5 seconds after any Pump,
Ram, Seal, or Air Assist command.