Event
Event
Event
Type
Type
Type
Event
Event
Event Description
Description
Description
Error
Error
Error
Code
Code
Code
Cause
Cause
Cause
Fix
Fix
Fix
Alarm
Communication bus
power error
V1CC
Communication bus has lost power
Restore power to communication bus
Alarm
Control panel supply
pressure low
P1PS
Control supply pressure sensor
reads pressure less than the
minimum 30 psi required for
operation or less than 5 psi below
largest pressure required by the
current recipe
Increase supply air pressure or reduce
pressure required by the current recipe
Alarm
Control supply
pressure sensor error
WMPC
Control supply pressure
sensor reports an error
Check control supply pressure sensor
and wiring
Alarm
Emergency stop or I/O
power error
V1CE
I/O has lost power
Restore I/O power, reset E-stop button
Alarm
External interlock #1
open
EBN1
Interlock #1 is enabled and tripped
Close or disable interlock #1
Alarm
External interlock #2
open
EBN2
Interlock #2 is enabled and tripped
Close or disable interlock #2
Alarm
Laser position sensor
error
WMCL
Laser sensor reports an error
Check Laser sensor and wiring
Alarm
Laser sensor
obstructed
L9CL
An obstruction or unintended target
of the position sensor has been
detected
Ensure the laser has a clear line of sight
to the target
Alarm
Pump supply pressure
low
P1PP
Pump supply pressure sensor
reads pressure more than 5 psi
below the pressure being driven
Increase supply air pressure or reduce
pressure required by the current recipe
Alarm
Pump supply pressure
sensor error
WMPP
Pump supply pressure
sensor reports an error
Check pump supply pressure sensor and
wiring
Alarm
Ram movement
timeout
EU1R
Upward ram movement has not
reached the minimum height
when the ram movement timeout
completes
Check ram for obstructions to movement,
manually raise ram