Electro-pneumatic Control Panel Display Screens
Automatic
Automatic
Automatic Screen
Screen
Screen
Feedback enabled
Feedback disabled
NOTES:
NOTES:
NOTES:
• To prime a full tote for automatic operation, press
and hold the green start button to advance the
ram downwards. Before reaching the top of the
tote, the pumps will begin to pump slowly and the
ram seal will partially inflate so that an overfilled
tote will not spill over. Continue holding the start
button until the ram plate is below the top of the
tote and the automatic sequence takes over. If the
button is released prior to the automatic sequence
beginning, will cause ram movement to cease.
Press and hold the start button to resume.
• When the partial tote setting is selected, pump
operation is delayed until the start button is
released and the ram plate is located below the rim
of the tote. If the ram plate is not below the rim
of the tote when the start button is released, ram
movement ceases.
• If feedback is enabled in system settings:
– The Current Job field is active. The Current Job
box logs how much material has been dispensed
since the previous job was completed.
– The Batching checkbox is active. Selecting the
Batching checkbox enables the Batch Amount
numeric field and enters the value defined in
the selected recipe Default Batch Size field.
When the specified amount has been dispensed,
the evacuation will cease and await further
instruction.
3A5416E
33