Electro-pneumatic Control Panel Display Screens
Inputs
Inputs
Inputs to
to
to the
the
the Allen
Allen
Allen---Bradley
Bradley
Bradley Controller
Controller
Controller
Variable
Variable
Variable Name
Name
Name
Data
Data
Data Type
Type
Type
Possible
Possible
Possible
Values
Values
Values
Notes
Notes
Notes
BR2AB_systemState
DINT
0 (Sys Busy),
1 (Standby),
2 (Manual
Run), 3 (Auto
Run)
N/A
BR2AB_containerLow
BOOL
TRUE,
FALSE
N/A
BR2AB_containerEmpty
BOOL
TRUE,
FALSE
N/A
BR2AB_sealInflated
BOOL
TRUE,
FALSE
N/A
BR2AB_systemLoaded
BOOL
TRUE,
FALSE
N/A
BR2AB_batchSequenceComplete
BOOL
TRUE,
FALSE
This will only be set if batch target
has been achieved. If the batching
sequence ends by emptying the container,
the “BR2AB_autoSequenceComplete”
variable will be set instead.
BR2AB_autoSequenceComplete
BOOL
TRUE,
FALSE
This will be set when an Auto sequence
completes, or a Batch sequence empties
a container before reaching the target
batch amount.
BR2AB_currentJobNumber
DINT
DINT
N/A
BR2AB_ramPosition_in
REAL
REAL
Identifies the distance from the laser
position sensor to the top beam or plate of
the system. Units are inches.
BR2AB_jobAmountMass_lbs
REAL
REAL
Amount of material pumped in the current
job if a "Mass" type feedback is selected in
system settings. Otherwise, this variable
has a value of -1. Units in pounds.
BR2AB_jobAmountVolume_gal
REAL
REAL
Amount of material pumped in the current
job if a "Volume" type feedback is selected
in system settings. Otherwise, this
variable has a value of -1. Units in gallons.
BR2AB_scaleReading_lbs
REAL
REAL
Identifies the current value of a scale if a
scale is connected and configured in the
system. Units in pounds.
BR2AB_evnt_eventTimestamp
DINT
DINT
Timestamp in Unix time.
BR2AB_evnt_eventGroup
SINT
0 (Alarm), 1
(Deviation), 2
(Advisory)
Has a value of 255 if no events need
acknowledgment. See Event Table.
BR2AB_evnt_eventIndex
SINT
SINT
Has a value of 255 if no events need
acknowledgment. See Event Table.
BR2AB_evnt_acknowledge
BOOL
TRUE,
FALSE
N/A
56