Electro-pneumatic Control Panel Display Screens
Outputs
Outputs
Outputs from
from
from the
the
the Allen
Allen
Allen---Bradley
Bradley
Bradley Controller
Controller
Controller
Variable
Variable
Variable Name
Name
Name
Data
Data
Data Type
Type
Type
Possible
Possible
Possible
Values
Values
Values
Notes
Notes
Notes
AB2BR_rec_primeTime_s
INT
INT
Corresponds to bit 10 in the
AB2BR_networkOverwriteBitfield
variable. Units in seconds.
AB2BR_rec_emptyTime_s
INT
INT
Corresponds to bit 11 in the
AB2BR_networkOverwriteBitfield
variable. Units in seconds.
AB2BR_rec_sealDeflateTime_s
INT
INT
Corresponds to bit 12 in the
AB2BR_networkOverwriteBitfield
variable. Units in seconds.
AB2BR_rec_airAssistTime_s
INT
INT
Corresponds to bit 13 in the
AB2BR_networkOverwriteBitfield
variable. Units in seconds.
AB2BR_rec_batchAmount-
Mass_lbs
REAL
REAL
Corresponds to bit 14 in the
AB2BR_networkOverwriteBitfield
variable. If batching is enabled, the
evacuation will halt when the amount
of material pumped matches this value.
Units in pounds.
AB2BR_rec_batchAmountVol-
ume_gal
REAL
REAL
Corresponds to bit 15 in the
AB2BR_networkOverwriteBitfield
variable. If batching is enabled, the
evacuation will halt when the amount
of material pumped matches this value.
Units in gallons.
AB2BR_batchEnabled
BOOL
TRUE,
FALSE
Corresponds to bit 16 in the
AB2BR_networkOverwriteBitfield
variable. This switches between an
"Auto" sequence and a "Batch" sequence.
AB2BR_networkOverwriteBitfield
DINT
Bitfield
This variable is used as a bitfield, where
every denoted output variable has a
corresponding bit. If the remote PLC
intends the SDU to read the value in
from the Ethernet/IP network interface
and make it active in the system, the
corresponding bit for that variable must
be set to TRUE in this bitfield. When a bit
is set to TRUE, any value changes from
the SDU's touchscreen (including loading
a new recipe) will be overwritten by the
network value, unless “Override Remote”
is checked on the SDU Network screen.
When a bit is FALSE, the SDU system
ignores the network value.
3A5402J