Troubleshooting
3A1602H
29
Status Code 6: High Motor
Temperature
Motor is running too hot.
1.
Motor temperature too high. Reduce pressure duty
cycle, gun tip size, or move Reactor E-8p to a cooler
location. Allow 1 hour for cooling.
2.
Check fan operation. Clean fan and motor housing.
Status Code 7: No Cycle Counter
Switch Input
Have not received input from cycle counter switch for 10
seconds after selecting Recirculation Mode.
1.
Check cycle counter switch connection to board
(J10, pins 5, 6), page 38 (figure control module wir-
ing connections).
2.
Check that magnet (224) and cycle counter switch
(223) are in place under B side motor end cover
(227). Replace if necessary.