Repair
3A1602H
43
Electric Motor
Test Motor
If motor is not locked up by pumps, it can be tested
using a 9 V battery.
1.
Open recirculating valves, disconnect J4 or J11
from control board, see F
IG
. 58, page 38.
2.
Touch jumpers from battery to motor connections.
Motor should turn slowly and smoothly.
Removal
1.
See
Before Beginning Repair
, page 33. Relieve
pressure, page 23.
2.
Carefully lay sprayer on it’s side on a level surface.
Rotate sprayer and rest upside down on cart handle
assembly.
NOTE:
Always use two people when lifting the sprayer
up on to a workbench.
3.
Remove screws (10) and control board cover (61) to
expose the control board (12).
4.
Disconnect all cables and connectors from board
(12).
5.
Unplug cable (94) from fan (202). See F
IG
. 63, page
44.
6.
Remove screws (13) and board (12).
7.
Remove screws (10).
8.
Feed proportioner cables out of grommet in the cart
(1) and lift the cart off of the motor.
9.
Remove drive housing/pump assemblies and cart
handle assembly, page 39.
F
IG
. 62: Electric Motor Removal
10 (x4)
61
13 (x7)
12
10 (x4)
TI17470a
Summary of Contents for Reactor E-8p 3A1602H
Page 16: ...Setup 16 3A1602H 12 Install fluid tubes 36...
Page 36: ...Repair 36 3A1602H FIG 56 Function Knob Potentiometer ti17465a 10 61 12 16a 23 22 87 16 N S P...
Page 40: ...Repair 40 3A1602H FIG 59 Pressure Transducer Connection 35 ti17467a 33...
Page 56: ...Dimensions 56 3A1602H Dimensions 34 58 in 87 8 cm 24 12 in 61 3 cm 15 06 in 38 3 cm TI17120a...