Important Isocyanate (ISO) Information
3A1602H
7
Important Isocyanate (ISO) Information
Isocyanates (ISO) are catalysts used in two component materials.
Isocyanate Conditions
Spraying or dispensing fluids that contain isocyanates creates potentially harmful mists, vapors, and atom-
ized particulates.
•
Read and understand the fluid manufacturer’s warnings and
Safety Data Sheet (SDS) to know specific
hazards and precautions related to isocyanates.
•
Use of isocyanates involves potentially hazardous procedures. Do not spray with this equipment unless
you are trained, qualified, and have read and understood the information in this manual and in the fluid
manufacturer’s application instructions and SDS.
•
Use of incorrectly maintained or mis-adjusted equipment may result in improperly cured material.which
could cause off gassing and offensive odors. Equipment must be carefully maintained and adjusted
according to instructions in the manual.
•
To prevent inhalation of isocyanate mists, vapors and atomized particulates, everyone in the work area
must wear appropriate respiratory protection. Always wear a properly fitting respirator, which may include
a supplied-air respirator. Ventilate the work area according to instructions in the fluid manufacturer’s SDS.
•
Avoid all skin contact with isocyanates. Everyone in the work area must wear chemically impermeable
gloves, protective clothing and foot coverings as recommended by the fluid manufacturer and local reg-
ulatory authority. Follow all fluid manufacturer recommendations, including those regarding handling of
contaminated clothing. After spraying, wash hands and face before eating or drinking.
•
Hazard from exposure to isocyanates continues after spraying. Anyone without appropriate personal pro-
tective equipment must stay out of the work area during application and after application for the time
period specified by the fluid manufacturer. Generally this time period is at least 24 hours.
•
Warn others who may enter work area of hazard from exposure to isocyanates. Follow the recommen-
dations of the fluid manufacturer and local regulatory authority. Posting a placard such as the following
outside the work area is recommended:
TOXIC FUMES
HAZARD
DO NOT ENTER
DURING
SPRAY FOAM APPLICATION
OR FOR ___ HOURS AFTER
APPLICATION IS COMPLETE
DO NOT ENTER UNTIL:
DATE:
TIME:
____________
____________
Summary of Contents for Reactor E-8p 3A1602H
Page 16: ...Setup 16 3A1602H 12 Install fluid tubes 36...
Page 36: ...Repair 36 3A1602H FIG 56 Function Knob Potentiometer ti17465a 10 61 12 16a 23 22 87 16 N S P...
Page 40: ...Repair 40 3A1602H FIG 59 Pressure Transducer Connection 35 ti17467a 33...
Page 56: ...Dimensions 56 3A1602H Dimensions 34 58 in 87 8 cm 24 12 in 61 3 cm 15 06 in 38 3 cm TI17120a...