Setup
3A1602H
21
7.
Set function knob to Slow Recirc
or Fast Recirc
.
8.
When clean solvent exits both recirculation tubes,
set the function knob to Stop/Park
.
9.
Insert inlet tubes into pails. See
Connect Fluid Inlet
Tubes
, page 21.
10. Set the Recirc/Spray valves to Spray.
11. Run until material exits gun manifold.
Connect Fluid Inlet Tubes
1.
Loosen containment knob.
2.
Remove suction tube caps and place in contain-
ment tray.
3.
Insert each fluid inlet tube through the pour spout on
the appropriate five-gallon pail. Tighten the ring to
the pour spout.
NOTE:
Use a drill and mixing blade to mix filled or sepa-
rated materials in the pail before placing fluid inlet tube
into the pail.
F
IG
. 21
F
IG
. 22
OR
+
-
+
-
TI17128b
TI17132a
F
IG
. 23
NOTICE
To prevent cross-contamination of fluids and equip-
ment parts,
never
interchange component A (isocya-
nate) and component B (resin) parts or containers.
Label one pail “A” and the other “B”, using the red and
blue labels provided. Always double check which
material you have before placing fluid inlet tube into
the pail.
Ring
TI17125a
Summary of Contents for Reactor E-8p 3A1602H
Page 16: ...Setup 16 3A1602H 12 Install fluid tubes 36...
Page 36: ...Repair 36 3A1602H FIG 56 Function Knob Potentiometer ti17465a 10 61 12 16a 23 22 87 16 N S P...
Page 40: ...Repair 40 3A1602H FIG 59 Pressure Transducer Connection 35 ti17467a 33...
Page 56: ...Dimensions 56 3A1602H Dimensions 34 58 in 87 8 cm 24 12 in 61 3 cm 15 06 in 38 3 cm TI17120a...