18
308986
Installation – Optional Solvent Pump
NOTE:
The optional solvent pump is not offered as a
kit; order parts as needed. These instructions assume
that the pump is being mounted to the back of the
stand offered in this manual. The Typical Installations
on pages 7 and 9
show
s
an alternate installation.
Adjust your installation according to your specific
needs.
1.
Mount the solvent pump bracket (310) on the back
of the stand.
2.
Mount the pump (306) to the bracket using the
hardware supplied with the pump.
3.
Use the existing proportioning pump air
regulator (5) to supply air to the solvent pump.
Remove the plug from the back of the swivel
union (3) and install the adapter (301). Rotate the
regulator gauge elbow (4) so the gauge is facing
the operator.
4.
Couple the hose (303) and couplings (302).
Connect the hose (303) to the adapter (301).
5.
Install the other adapter (301), needle valve (304)
and adapter (305) to the pump inlet.
6.
Connect the adapter (307), elbow (308) and fluid
hose (309) to the pump outlet.
7.
Install a fluid shutoff valve (311) at the mixer
manifold swivel union (15). This valve is used to
prevent resin or hardener from backing up into the
solvent system, and to isolate the solvent system
for service. Connect the solvent inlet hose (309).
8.
Connect the suction hose assembly (312) to the
pump intake.
309
310
312
308
307
305
303
301
304
314
313
301
309
311
15
306
316
315
Fig. 14
302,
303
302
5
4
3
A
B
02902
B
A
Monarch 10:1 Shown