10
308986
Installation
Bare Pumps
Bare pumps, with relief valves and inlet kits but without
stands, are available for those installations which
require a highly customized system. For a safe and
efficient system, Graco recommends that the air and
fluid components supplied with the Wall Mount and
Stand models also be used in customized systems. In
addition, the accessories shown in the Typical Installa-
tion drawings and discussed in the following pages of
this manual should be used.
Be sure all accessories are sized properly for the air
and fluid requirements of your system.
Read all instructions in the Installation section for
further details.
NOTES:
1.
Models with three displacement pumps always use
the two outer displacement pumps to supply the
resin and the middle displacement pump to supply
the hardener.
2.
Label all pumps, hoses, fluid regulators, etc. to
indicate whether they are for the resin side or
hardener side of the system.
Mounting the Pump
Mount the pump to suit your installation. The bare
pump can be mounted on a wall bracket or on a stand.
See the Mounting Hole Layout on page 19.
For a wall mount,
be sure the bracket and wall are
strong enough to support the pump, accessories,
plumbing and stress caused by pump operation.
Locate the bracket about 5 ft (1.5 m) above the floor.