308986
7
Typical Installation
About Typical Installations
The typical installations shown below and on pages 8
and 9 are only guidelines to setting up a complete
proportioning system. For clarity, various components
are shown in the correct order but may not be shown in
the exact position of the installed system. For assis-
tance in designing your system, contact your nearest
Graco representative.
NOTE:
When pressure feeding the proportioning
pump, mount fluid pressure gauges (J) at the propor-
tioning pump inlets to monitor proper adjustment of the
feed pump pressures.
Never exceed 400 psi on the
inbound fluid pressure and never exceed 25% of
the Hydra-Cat pump outbound fluid pressure on
the feed supply.
Two Displacement Pumps,
with Feed Pumps
1
See note above
Connect to drain bottle.
See Fig. 6, page 13
2
KEY
A
Bleed-type master
air valve
B
Air filter
C
Air lubricator
D
Pump runaway valve
E
Pump air regulator
F
Feed pump
G
Ground wire
H
Proportioning pump
J
Fluid pressure gauge
K
Check valve
L
Automatic pressure relief
valve
M
Fluid filter (Optional)
N
Mixer manifold
P
Fluid drain valve
Q
Fluid shutoff valve
R
Static mixer
S
Dispense valve
T
Fluid regulator
U
Solvent pump
V
Fluid strainer
Fig. 1
B A
F G
A
E
H
K
L
M
N
P
Q
R
Q
K
S
M
J
T
Q
A
E
V
U
1
02911
2
C
D