background image

4

308487

Installation

Typical Installations

Fig. 1 shows a typical hose reel installation.  Fig. 2
shows how these dispense valves can be installed on
a console.

Do not use this electronic metered dispense
valve on non-Graco consoles.  Such use could
result in the trigger becoming inadvertently
pressed while the dispense valve is stowed.

CAUTION

Fig. 1

L

M

K

N

J

06174B

H

KEY DESCRIPTION

H

Thermal relief kit (required)  Part No. 235998

Install downstream from pump.

J

Fluid shut-off valve

K

Hose

L

Hose reel fluid inlet hose

M

Hose reel

N

Metered dispense valve

The typical installation shown in Fig. 1 is only a guide;
it is not a complete system design.  Contact your
Graco distributor for assistance in designing a system
to suit your particular needs.

This dispense valve is not designed for in-line
installation.  Do not install with a shut-off valve
on the outlet side of the meter.  Such installation
could result in damage to the meter housing
cover.

CAUTION

Mounting Bracket

Mounting bracket 196471 is available for resting an
EM5 dispense valve on a console.  See Fig. 2.

Do not obstruct the trigger of this dispense
valve, and do not set the unit down resting on its
trigger, or it might not stop dispensing.

CAUTION

Fig. 2

mounting
bracket
196471

NOTE:  

When using the EM5 with the rigid oil

extension on a dispense console, the rigid tube (5a)
should be oriented with the 75

_

 bend closest to the

nozzle, as shown below.  This prevents interference
when used with a dispense console.

5a

5a

TI0274

Summary of Contents for EM5 238457

Page 1: ...ht 1996 Graco Inc is registered to I S EN ISO 9001 STANDARD EM5tElectronic Metered Dispense Valves For dispensing petroleum based lubricants and antifreeze 1000 psi 7 MPa 69 bar Maximum Working Pressure 5 gpm 18 9 lpm Maximum Flow Rate Factory Set to Measure in Liters Canadian Weights Measures approved Model 238457 75_ bend 3 8 in rigid tube Model 238458 3 8 in coupled flexible hose Model 238459 1...

Page 2: ...imum working pressure of the lowest rated system component See the Technical Data on page 22 for the maximum working pressure of this component D Use fluids and solvents that are compatible with the equipment wetted parts See the Technical Data section of all equipment manuals Read the fluid and solvent manufacturer s warnings D Route hoses away from traffic areas sharp edges moving parts and hot ...

Page 3: ...ing this equipment stop dispensing immediately Do not use the equipment until you identify and correct the problem D Provide fresh air ventilation to avoid the buildup of flammable fumes from solvents or the fluid being dispensed D Keep the dispensing area free of debris including solvent rags and spilled gasoline D Do not smoke while flammable fluids or fumes are in the dispensing area D You must...

Page 4: ... design Contact your Graco distributor for assistance in designing a system to suit your particular needs This dispense valve is not designed for in line installation Do not install with a shut off valve on the outlet side of the meter Such installation could result in damage to the meter housing cover CAUTION Mounting Bracket Mounting bracket 196471 is available for resting an EM5 dispense valve ...

Page 5: ...ore you install the metered valve Contaminated lines could cause the valve to leak CAUTION 1 If this is an existing installation go to step 7 Steps 3 through 6 are the Flushing Procedure 2 Make sure the main fluid outlet valve at the pump is closed the air pressure to the pump motor is adjusted and the air valve is open Slowly open main fluid valve 3 Close the fluid shut off valve J at each dispen...

Page 6: ...ow and tighten it NOTE The flexible hose 6a can also be threaded directly into the meter outlet without the elbow or sealing nut Model 238459 This nozzle assembly can be configured two ways See See Fig 4 a Thread a sealing nut 7c onto the tube 7a with the PTFE side facing out b Thread the tube 7a into the meter outlet at lease three full turns position it for proper alignment and tighten the seali...

Page 7: ...dispense valve before you use it Set the system flow to the desired flow rate which is typically 1 5 gpm Do not exceed a 5 gpm flow rate Grounding FIRE AND EXPLOSION HAZARD The movement of fluids through the dispensing system generates static electricity The static electricity can cause volatile fumes to ignite resulting in explosion and fire The dispensing system must grounded WARNING Proper grou...

Page 8: ...8 308487 Notes ...

Page 9: ... predeter mined amount has been dispensed It does not automatically stop dispensing D Asleep Awake Asleep is a battery saving mode in which the dis play goes blank after two minutes of inactivity The display comes awake from sleep mode when you press any button on the keypad or when you squeeze the trigger to dispense fluid Keypad Buttons The buttons on the keypad and their functions are as follow...

Page 10: ...can press the Reset button again to toggle between zero and the previously displayed resettable total To lock in the displayed value and advance to the Units of Measurement menu press the Auto button OR D Press the Auto button The currently displayed value is stored and the display advances to the Units of Measurement menu 06044 R TOTAL GAL Maximum Working Pressure 70 bar 1000 PSI Min Dispense Vol...

Page 11: ...d the display advances to the Reset to Zero Option menu 06044 AUTO QTS Maximum Working Pressure 70 bar 1000 PSI Min Dispense Volume 0 5 liter 0 13 gal Minimum Flow Rate 1 0 l min 0 26 gpm Maximum Flow Rate 15 0 l min 3 26 gpm Reset to Zero Option In this menu you can set whether or not the unit will automatically reset to zero after two minutes of inactiv ity On means that the unit will automatica...

Page 12: ...ctor Metric Measurement Measuring in liters and 1 liter is dispensed Error in Cubic Centimeters cm3 Change Calibration Factor by 56 69 102 47 19 85 37 69 68 28 35 51 18 84 34 9 34 17 0 000 no change 9 34 17 18 84 34 28 35 51 37 69 68 47 19 85 56 69 102 Formulas If the dispensed amount according to the markings on the flask is greater than the displayed amount New CF Old CF Error in cm3 0 555 If th...

Page 13: ...ration button The calibration factor is shown on the display as shown below 06044 CAL Maximum Working Pressure 70 bar 1000 PSI Min Dispense Volume 0 5 liter 0 13 gal Minimum Flow Rate 1 0 l min 0 26 gpm Maximum Flow Rate 15 0 l min 3 26 gpm 4 Press the Calibration button again The first digit blinks which indicates that you can change it 5 Press the 10 1 0 and 0 1 buttons to advance the blinking d...

Page 14: ...to button The stored predetermined dispense amount is shown on the display if an amount is stored 2 If you do not want to change the predetermined dispense amount shown on the display skip this step If you want to change the amount do the following Press the 10 button to change the 10s digit press the 1 0 button to change the 1s digit and press the 0 1 button the change the first decimal digit 3 S...

Page 15: ...er 0 13 gal Minimum Flow Rate 1 0 l min 0 26 gpm Maximum Flow Rate 15 0 l min 3 26 gpm 3 Press the Total button again The resettable total amount is shown on the display in the current units as shown below 06044 R TOTAL GAL Maximum Working Pressure 70 bar 1000 PSI Min Dispense Volume 0 5 liter 0 13 gal Minimum Flow Rate 1 0 l min 0 26 gpm Maximum Flow Rate 15 0 l min 3 26 gpm 4 Press the Total but...

Page 16: ...ge 13 Oil leaks from swivel swivel boot or plastic housing Swivel 3 connection to meter is loose Hose connection to swivel 3 is loose Torque the fitting to 20 to 25 ft lb 27 to 34 N m Apply sealant to threads of hose and tighten the connection See step 9 in Installation Procedure on page 5 Oil leaks from where fluid out let tube connects to housing Outlet tube or sealing nut or street elbow is loo...

Page 17: ... line Err 2 Switch Error Error occurred with pick up in internal gear or flow range is too high OR Air was pumped through the line OR Unit was dropped or unit encoun tered excessive vibration during shipping Ensure that your flow rate is not higher than 5 gpm For further assis tance contact your Graco distributor Purge air from the line Press the Reset button at start up Err 3 Unit had to default ...

Page 18: ...f the meter and tampering with the meter settings Sealing provisions accommodate typical Weights and Measures official seal wires and security requirements See Fig 6 Tabs for tamper evident security seals one on each side of meter pre vent opening of the cover 06042C Fig 6 Replacing the Filter The filter 25 is replaceable To replace the filter do the following 1 Relieve the pressure WARNING To red...

Page 19: ...to 140 to 150 in lb 16 to 17 N m NOTE Take care that the spring 16a does not get pinched when you install the valve stem assembly 16 into the meter housing 7 Place the trigger 15 on the valve stem assembly 16b put the cover 1 together thread in the six screws that hold the cover together and torque to 7 to 10 in lb 0 8 to 1 1 N m Replacing the Nozzle If the nozzle 5b 6b or 7b begins to leak replac...

Page 20: ...8 in coupled 1 6b 239829 NOZZLE automatic 1 6c 113419 NUT seal 3 8 in 18 NPT 1 6d 155699 ELBOW street 1 Ref No Part No Description Qty 7 238887 NOZZLE ASSEMBLY For Model 238459 includes 7a to 7d 7a 191038 TUBE rigid 15_ bend 3 8 in 1 7b 238371 NOZZLE gear lube 1 7c 113419 NUT seal 3 8 in 18 NPT 2 7d 155699 ELBOW street 1 8 113716 BATTERY standard 9V alkaline 1 15 191046 TRIGGER 1 16 240453 KIT val...

Page 21: ... 1 16 2 2 Torque to 140 to 150 in lb 15 8 to 16 9 N m 2 3 4 25 1 15 24 3 Apply lubricant when reassembling 3 8 6c 6a 6 Apply thread sealant when reassembling 7 6 Torque to 20 to 25 ft lb 27 to 34 N m 7 27 These parts are included in Valve Repair Kit 240453 which can be ordered separately 6d 7a 7c 7c 7c 7c 7d 7d 7b 7b 7a 5b 5a 5c 6b 28 ...

Page 22: ... zinc stainless steel 304 LCP carbon steel polyurethane nitrile rubber Fluid compatibility lubricating oils antifreeze mixtures Meter valve assembly pressure loss At 1 5 gpm 5 7 lpm with 30 weight oil at 70_ F 21_ C 17 psi 0 12 MPa 1 2 bar Accuracy 0 5 percent Repeatability 0 15 percent Default settings for calibration factor 10W 30 oil 6815 antifreeze 7230 Tested in No 10 motor oil Flow rates var...

Page 23: ...308487 23 Dimensional Drawing 06042C A 14 0 in 356 mm outlet to end of swivel cover B A B C 3 25 in 83 mm widest cross section C 2 75 in 70 mm keypad to bottom of cover ...

Page 24: ...ny other warranties express or implied including warranty of merchantability or warranty of fitness for a particular purpose and of any non contractual liabilities including product liabilities based on negligence or strict liability Every form of liability for direct special or consequential damages or loss is expressly excluded and denied In no case shall Graco s liability exceed the amount of t...

Reviews: