Troubleshooting
Error Codes
If an error code is shown on the display, as shown at
right, you can press the Reset button to clear the error
code and see the dispensed amount. Even in an error
condition, the unit keeps track of the amount dis-
pensed.
06044
Maximum Working Pressure: 70 bar (1000 PSI)
Min. Dispense Volume
0.5 liter
(0.13 gal)
Minimum Flow Rate
1.0 l/min.
(0.26 gpm)
Maximum Flow Rate
15.0 l/min.
(3.26 gpm)
Err 1
Flow rate is higher than 5 gpm.
OR
Air was pumped through the line.
Adjust the flow rate so it is not higher
than 5 gpm.
Purge air from the line.
Err 2
Switch Error: Error occurred with
pick-up in internal gear, or flow
range is too high.
OR
Air was pumped through the line.
OR
Unit was dropped, or unit encoun-
tered excessive vibration during
shipping.
Ensure that your flow rate is not
higher than 5 gpm. For further assis-
tance, contact your Graco distributor.
Purge air from the line.
Press the Reset button at start-up.
Err 3
Unit had to default to factory-set
values for calibration factors.
This
error can occur only after you
replace the battery, and only if the
unit detects an input calibration
factor that is out of the acceptable
range.
If you changed the calibration factor
from the factory-set value, ensure
that it is correct according to the
tables in
Calculating the
Calibration Factor
on page 12.