308487
9
Setup
Terms
The following terms are shown on the display and/or
used often in this instruction manual.
D
R–TOTAL: Resettable Total
Displayed to show the cumulative amount that the
dispense valve has dispensed. It can be reset to
zero.
D
TOTAL: Non-Resettable Total
Displayed to show the cumulative amount that the
dispense valve has dispensed for the history of the
unit. It cannot be reset.
D
Standard Dispense Mode
The dispense mode in which the display always
counts up from zero or from where it recently
stopped in Standard dispense mode. There are no
warning beeps for predetermined dispense
amounts.
D
Auto Alarm Dispense Mode
The dispense mode in which the unit beeps to
indicate that the predetermined amount has been
dispensed.
It does not automatically stop dis-
pensing.
D
Predetermined Dispense Amount
A user-entered amount to be dispensed, in which
the display can be set to count up from zero or
down from the entered amount in Auto Alarm
mode. The unit beeps to indicate that the predeter-
mined amount has been dispensed.
It does not
automatically stop dispensing.
D
Asleep / Awake
Asleep
is a battery-saving mode in which the dis-
play goes blank after two minutes of inactivity. The
display comes
awake
from sleep mode when you
press any button on the keypad or when you
squeeze the trigger to dispense fluid.
Keypad Buttons
The buttons on the keypad and their functions are as
follows (see the figure below):
D
10, 1.0,
and
0.1
Used to enter dispense amounts.
D
TOTAL
Used to see the resettable total, non-resettable
total, and calibration factor.
D
RESET
*
Used to reset the displayed amount to zero and to
enter the Standard dispense mode.
D
AUTO
*
Used to enter the Auto Alarm dispense mode, in
which you enter an amount, and the unit beeps to
indicate when that amount is dispensed.
It does
not automatically stop dispensing
.
*
The Auto and Reset buttons are used together
(pressed simultaneously) to access the setup
menus, in which you select dispensing options.
NOTE:
All buttons are disabled while fluid is being
dispensed.
06044
AUTO
GAL
Maximum Working Pressure: 70 bar (1000 PSI)
Min. Dispense Volume
0.5 liter
(0.13 gal)
Minimum Flow Rate
1.0 l/min.
(0.26 gpm)
Maximum Flow Rate
15.0 l/min.
(3.26 gpm)
Summary of Contents for EM5 238457