10
308487
Setup
Selecting Dispensing Options
This is the procedure for setting or changing the resettable total, units of measurement, predetermined dispense
amount, and the reset-to-zero option:
1.
If the display is asleep, wake it up by pressing any button on the keypad.
2.
To enter the dispensing options menus,
press and hold the Reset and Auto buttons simultaneously
for two
seconds.
The first menu is the Resettable Total menu, which is described in the first subsection below. You can advance
through the menus by pressing the Auto button repeatedly. You will know which menu you are in, because a
menu indicator will be blinking in the display. The value that is displayed when you leave each menu and
advance to the next is the value that gets stored.
Resettable Total
In this menu, you can reset the resettable total to zero
or leave it unchanged. The resettable total accumu-
lates until the next time it is manually reset.
1.
If you have not already entered the dispensing
options menus, do steps 1 and 2 in
Selecting
Dispensing Options
above.
2.
With
R–TOTAL
blinking and the current resettable
total displayed, as shown below, do
ONE
of the
following two options:
D
Press the Reset button.
The resettable total is set to zero, and
00000 GAL
or
00000 LITERS
is displayed.
You can press the Reset button again to toggle
between zero and the previously displayed resettable
total. To lock in the displayed value and advance to
the Units of Measurement menu, press the Auto
button.
OR
D
Press the Auto button.
The currently displayed value is stored, and the display
advances to the Units of Measurement menu.
06044
R-TOTAL
GAL
Maximum Working Pressure: 70 bar (1000 PSI)
Min. Dispense Volume
0.5 liter
(0.13 gal)
Minimum Flow Rate
1.0 l/min.
(0.26 gpm)
Maximum Flow Rate
15.0 l/min.
(3.26 gpm)
Units of Measurement
In this menu, you can set the units of measurement to
quarts, gallons, pints, or liters.
1.
If you have not already entered the dispensing
options menus, do steps 1 and 2 in
Selecting
Dispensing Options
above.
2.
Press the Auto button repeatedly until
QTS
,
GAL
,
LITERS,
or
PTS
blinks to indicate that you are in
the Units-of Measurement menu.
3.
With
QTS
,
GAL
,
LITERS,
or
PTS
blinking, as
shown below, do
ONE
of the following two options:
D
Press the Reset button.
Each time you press the Reset button, the display
scrolls to the next unit of measurement. To lock in the
new unit of measurement and advance to the Calibra-
tion Factor menu, press the Auto button.
OR
D
Press the Auto button.
The displayed unit of measurement is retained, and
the display advances to the Predetermined Dispense
Amount menu.
GAL
06044
Maximum Working Pressure: 70 bar (1000 PSI)
Min. Dispense Volume
0.5 liter
(0.13 gal)
Minimum Flow Rate
1.0 l/min.
(0.26 gpm)
Maximum Flow Rate
15.0 l/min.
(3.26 gpm)