308487
11
Setup
Predetermined Dispense Amount
In this menu, you can specify an amount to be dis-
played when you enter the Auto Alarm dispense mode.
Typically, you would enter the amount you most fre-
quently dispense.
1.
If you have not already entered the dispensing
options menus, do steps 1 and 2 in
Selecting
Dispensing Options
on page 10.
2.
Press the Auto button repeatedly until
AUTO
and a
dispense amount
blink to indicate that you are in
the Predetermined Dispense Amount menu. This
is the amount that is displayed when the Auto
button is pressed during normal operation.
3.
With
AUTO
blinking and the stored auto preset
amount displayed, as shown below, do
ONE
of the
following two options:
D
Press the 10 button to change the 10s digit,
the 1.0 button to change the 1s digit, and
the 0.1 button the change the first decimal
digit. What you enter is the new predeter-
mined dispense amount.
In the figure below, the arrows point from the num-
bered buttons on the keypad to the corresponding
digits in the display.
NOTE:
If you press and hold the 10, 1.0, or 0.1 but-
tons, the digits advance rapidly.
To store the displayed predetermined dispense amount
in memory and advance to the Reset-to-Zero Option
menu, press the Auto button.
OR
D
Press the Auto button.
The displayed predetermined dispense amount is
retained, and the display advances to the Reset-to-
Zero Option menu.
06044
AUTO
QTS
Maximum Working Pressure: 70 bar (1000 PSI)
Min. Dispense Volume
0.5 liter
(0.13 gal)
Minimum Flow Rate
1.0 l/min.
(0.26 gpm)
Maximum Flow Rate
15.0 l/min.
(3.26 gpm)
Reset-to-Zero Option
In this menu, you can set whether or not the unit will
automatically reset to zero after two minutes of inactiv-
ity.
On
means that the unit will automatically reset to
zero after two minutes of inactivity.
OFF
means that
the unit will remain at the current total indefinitely, or
until the Reset button is pushed.
1.
If you have not already entered the dispensing
options menus, do steps 1 and 2 in
Selecting
Dispensing Options
on page 10.
2.
Press the Reset button repeatedly until the clock
icon and either
On
or
OFF
is displayed to indicate
that you are in the Reset-to-Zero Option menu.
3.
With the clock icon and either
On
or
OFF
dis-
played, as shown below, do
ONE
of the following
two options:
D
Press the Reset button.
You can press the Reset button again to toggle
between
On
and
OFF
. To lock in the displayed value,
press the Auto button.
The EM5 beeps and returns to the Standard dispense
mode to indicate that you have exited the dispensing
options menus.
OR
D
Press the Auto button.
The EM5 beeps and returns to the Standard dispense
mode to indicate that you have exited the dispensing
options menus.
06044
Maximum Working Pressure: 70 bar (1000 PSI)
Min. Dispense Volume
0.5 liter
(0.13 gal)
Minimum Flow Rate
1.0 l/min.
(0.26 gpm)
Maximum Flow Rate
15.0 l/min.
(3.26 gpm)